# What is WVTR Testing? A Complete Guide for Packaging Engineers

- Link: https://flexitest.in/blogs/blog-what-is-wvtr-testing-guide-packaging-engineers/
- Published: 2026-08-07T12:58:54+05:30
- Author: kamal

*     Complete Technical Guide

# What is WVTR Testing? A Complete Guide for Packaging Engineers

Understand Water Vapour Transmission Rate, testing methods, standards, test conditions,
and how to choose the right WVTR tester for your packaging application.

 1. [Home](https://flexitest.in)
 2. [Blog](https://flexitest.in/category/blog/)
 3. What is WVTR Testing? A Complete Guide for Packaging Engineers

 What does WVTR mean?

 Why WVTR matters for packaging

 How WVTR testing is done

 Test conditions

 Materials tested

 WVTR vs OTR

 Choosing a WVTR tester

 Standards reference

 FAQ

If you work in packaging quality control, you’ve almost certainly come across the
term WVTR.

A packaging film may look perfect, seal properly, and pass visual inspection-yet
still allow enough moisture to reduce product shelf life. WVTR testing helps packaging
engineers quantify how effectively a material resists water vapour under controlled
temperature and humidity conditions.

Whether you’re testing flexible films for food packaging, pharmaceutical blister
packs, or industrial laminates, **Water Vapour Transmission Rate (WVTR)** is one
of the most important parameters you need to measure – and understand.

In this guide, we explain exactly what WVTR testing is, how it works, which test
standards apply, what the numbers mean, and how to choose the right instrument for
your application.

 *  📌 **Quick Summary**
 *     WVTR = rate of water vapour passing through a material over time
 *     Key standards: ASTM E96, ASTM F1249, ISO 15106-1 / 15106-2
 *     Critical for: food, pharma, flexible laminates, pouch manufacturing

 *     Lower WVTR = better moisture barrier = longer shelf life
 *     Two main methods: Gravimetric (cup) and IR / Electrolytic Sensor
 *     Unit: g/m²/day (grams per square metre per day)

## What does WVTR mean?

WVTR stands for **Water Vapour Transmission Rate**. It measures the amount of water
vapour that passes through a unit area of a material in a given time under specific
conditions of temperature and humidity.

The standard unit for WVTR is **g/m²/day** (grams per square metre per day). A lower
WVTR value means the material is a better moisture barrier.

   |  WVTR Value |  Barrier Level |  Typical Application |  
     |  < 0.1 g/m²/day |  Ultra-high barrier |  Pharmaceutical blisters, sterile medical packaging |  
  |  0.1 – 1.0 g/m²/day |  High barrier |  Snack food pouches, meat packaging, retort pouches |  
  |  1.0 – 10 g/m²/day |  Medium barrier |  General flexible packaging, coffee pouches |  
  |  > 10 g/m²/day |  Low barrier |  Industrial wrapping films, non-food applications |

**Note:** WVTR values cannot be compared directly unless the test method, temperature,
relative humidity, specimen thickness, and test area are considered.

## Why does WVTR matter for packaging?

Moisture is one of the primary causes of product degradation.

It leads to microbial growth, oxidation, clumping of powders, loss of crispness,
and reduced drug efficacy. Packaging materials are the first line of defence.

 *  Getting the WVTR of your packaging material wrong can result in:
 *     Shortened shelf life of food or pharmaceutical products
 *     Failed regulatory compliance (FSSAI, FDA, EU packaging regulations)
 *     Customer complaints and costly product recalls
 *     Loss of brand trust and market share

**WVTR testing gives you a quantifiable, reproducible measurement** that lets your
packaging development team choose the right film, verify supplier quality, and demonstrate
compliance to customers and regulators.

## How is WVTR testing done?

There are three principal methods used globally for WVTR measurement:

Method 1 - Gravimetric method (Cup method)

 ASTM E96 / E96M ISO 2528 IS 1060

A test specimen is sealed over a cup containing a desiccant or water. Placed in 
a controlled temperature and humidity environment, the cup is periodically weighed.
The change in weight over time gives the WVTR.

✓ Pros

Simple, low cost, no gas sensor needed. Suitable for any material thickness.

✗ Cons

Slow - test cycles of 24 hours to several days. Requires high-precision balance.

Method 2 - Infrared sensor method (Modulated NIR)

 ASTM F1249 ISO 15106-2

The film specimen separates a dry nitrogen stream from a humid air stream. Water
vapour passing through the film is detected by an infrared sensor - fast and accurate
for high-barrier films.

✓ Pros

Fast results (hours), high sensitivity, accurate for <0.1 g/m²/day, automated.

✗ Cons

Higher instrument cost. Requires appropriate calibration and periodic instrument
verification.

Method 3 - Electrolytic sensor (Coulometric) method

 astm F3199 ISO 15106-3

Water vapour permeating through the film is absorbed by a phosphorus pentoxide electrolytic
cell, generating a measurable current. Used for ultra-high-barrier applications.
Can measure WVTR as low as 0.0001 g/m²/day.

✓ Pros

Ultra-high sensitivity. Essential for pharma and flexible electronics.

✗ Cons

Highest instrument cost. Specialist calibration required.

   |  Method |  Best For |  Speed |  Sensitivity |  
     |

 ⚖️ Gravimetric

  |  General materials |   🐢 Slow  |   ◎ Moderate  |  
  |

 📡 IR Sensor

  |  Packaging films |   ⚡ Fast  |   ▲ High  |  
  |

 ⚗️ Electrolytic

  |  High-barrier materials |   ⚡ Fast  |   ★ Very High  |

## Test conditions - temperature and humidity

WVTR values are strongly influenced by temperature and relative humidity (RH). Always
report your test conditions alongside the WVTR value.

   |  Condition |  Temperature |  Relative Humidity |  Typical Use Case |  
     |  Standard |  23°C |  50% RH |  General packaging, Europe / ISO default |  
  |  Tropical |  38°C |  90% RH |  Pharma (ICH Zone IVb), food in tropical climates |  
  |  Accelerated |  40°C |  75% RH |  Pharma (ICH Zone III/IV standard) |

 In India, where temperature and humidity vary dramatically – especially in coastal
and tropical regions – testing at 38°C / 90% RH gives the most realistic performance
data for products distributed nationally.

## Which films and materials are tested?

 *  WVTR testing applies to virtually any flexible barrier material:
 *     Flexible packaging films: BOPP, PET, PE, PA (Nylon), EVOH multilayer laminates
 *     Aluminium foil laminates and metalized films
 *     Pharmaceutical blister foils and alu-alu laminates
 *     Paper and paperboard with barrier coatings
 *     Pouches and sachets (food, personal care, industrial)
 *     Breathable membranes and technical textiles
 *     Agricultural mulch films

### WVTR vs OTR - what's the difference?

WVTR and OTR are the two most important barrier properties in flexible packaging–
and they are often tested together.

Many food and pharmaceutical products are sensitive to both moisture and oxygen.
For example, a product may require low WVTR to prevent moisture absorption and low
OTR to reduce oxidation. In such applications, evaluating both properties provides
a more complete understanding of packaging barrier performance.

   |  Parameter |  WVTR |  OTR |  
     |  Full name |  Water Vapour Transmission Rate |  Oxygen Transmission Rate |  
  |  What it measures |  Moisture passing through film |  Oxygen passing through film |  
  |  Unit |  g/m²/day |  cc/m²/day (or mL/m²/day) |  
  |  Key standard |  ASTM E96, ASTM F1249, ISO 15106 |  ASTM D3985, ISO 15105-2 |  
  |  Critical for |  Biscuits, pharma, hygroscopic powders |  Meat, coffee, cheese, chips |  
  |  Detection method |  Gravimetric, IR sensor, Coulometric |  Coulometric, IR sensor |

Many packaging labs test both WVTR and OTR together. Multi-parameter combo instruments–
like the **Labthink Combo Tester C406H** – are designed to measure both on one platform.

## WVTR testing standards - quick reference

The right instrument depends on three factors: the barrier level of your material,
the test standard required by your customer or regulator, and your throughput needs.

![WVTR Gravimetric Method C360H](https://flexitest.in/wp-content/uploads/2025/04/
WVTR-C360H-e1745820737992.webp "What is WVTR Testing? A Complete Guide for Packaging
Engineers 1")

## General flexible packaging

Method : Gravimetric Recommended Instrument : Labthink C360H

 [ View Details → ](https://flexitest.in/packaging-testing-equipments/permeability-testing-instruments/wvtr-gravimetric-method-c360h/)

![Oxygen Transmission Rate Tester 3 Cells - C203H](https://flexitest.in/wp-content/
uploads/2025/04/OTR-C-203H-e1745819267320.webp "What is WVTR Testing? A Complete
Guide for Packaging Engineers 2")

Application : High-barrier laminates, food pouches

Method : IR Sensor Recommended Instrument : Labthink C203H

 [ View Details → ](https://flexitest.in/packaging-testing-equipments/permeability-testing-instruments/oxygen-transmission-rate-tester-3-cells-c203h/)

![Combo Tester 3 Cells C403H – OTR + WVTR](https://flexitest.in/wp-content/uploads/
2025/04/Combo-C403H-OTRWVTR-e1745820994990.webp "What is WVTR Testing? A Complete
Guide for Packaging Engineers 3")

Application : Pharmaceutical blisters, alu-alu foil

Method : Electrolytic Recommended Instrument : Labthink C303H

 [ View Details → ](https://flexitest.in/packaging-testing-equipments/permeability-testing-instruments/water-vapour-transmission-rate-tester-3-cells-c303h/)

![Combo Tester 6 Cells – C406H](https://flexitest.in/wp-content/uploads/2025/04/
Combo-C406H-e1745818853346.webp "What is WVTR Testing? A Complete Guide for Packaging
Engineers 4")

Application : WVTR + OTR on one unit

Method : IR / Coulometric Recommended Instrument : Labthink C406H

 [ View Details → ](https://flexitest.in/packaging-testing-equipments/permeability-testing-instruments/combo-tester-6-cells-c406h/)

Flexitest is the authorised distributor of **Labthink permeability testing instruments
in India**. Our application engineers can help you select the right model for your
specific films, standards, and test conditions.

 

### How to choose a WVTR tester

The right instrument depends on three factors: the barrier level of your material,
the test standard required by your customer or regulator, and your throughput needs.

##### WVTR testing standards - quick reference

ASTM E96 / E96M

Gravimetric dish method - water vapour transmission of materials

ASTM F1249

Modulated infrared sensor method - plastic films and sheeting

ISO 15106-1

Plastics - water vapour transmission rate (infrared sensor method)

ISO 15106-2

Electrolytic detection sensor method

ISO 2528

Sheet materials - water vapour transmission rate (gravimetric dish method)

IS 1060 (Part 2)

Indian Standard for water vapour transmission - Bureau of Indian Standards

 [ ⌊C406H Oxygen Water Vapor Transmission Rate Test System for permeability testing⌉ ](https://flexitest.in/packaging-testing-equipments/permeability-testing-instruments/wvtr-gravimetric-method-c360h/)

## 󠀁[Permeability Testing Machine Solutions ](https://flexitest.in/packaging-testing-equipments/permeability-testing-instruments/)󠁿

 [  Explore   ](https://flexitest.in/blogs/blog-what-is-wvtr-testing-guide-packaging-engineers/#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6IjE0NDQ4IiwidG9nZ2xlIjpmYWxzZX0%3D)

####  Submit Your Details to Download Brochure!

  Name

  Email

  Phone Number

  Company Name

  Company Location

   By clicking the button, I agree and consent to the company’s [Privacy Policy](https://flexitest.in/privacy-policy)

## FAQ's

 Frequently Asked Questions (FAQs) – Common questions from QC managers, procurement
officers, and R&D teams.

  What is a good WVTR value for food packaging?

It depends on the product. For moisture-sensitive foods like biscuits, chips, or
powders, a WVTR below 1.0 g/m²/day is generally required. For products like fresh
produce that need some breathability, a higher WVTR may be acceptable or even desirable.

  What is the difference between WVTR and MVTR?

 WVTR (Water Vapour Transmission Rate) and MVTR (Moisture Vapour Transmission Rate)
refer to the same measurement. MVTR is an older term, still used in some medical
and textile standards. Both measure the rate of water vapour passing through a material
and use the same units (g/m²/day).

  How long does a WVTR test take?

Gravimetric (cup) method tests typically take 24 to 72 hours per cycle. Modern infrared
sensor instruments like the Labthink W3/230 can produce results in 2–6 hours for
most packaging films, significantly reducing lab turnaround time.

  Can WVTR be tested on pouches and finished packaging?

Standard WVTR tests are performed on flat film specimens. For finished pouches, 
the whole-package transmission rate can be determined using a headspace or sealed-
pouch method – a different but related measurement. For most QC and supplier qualification
purposes, flat film testing is standard practice.

  Is WVTR testing required for export packaging?

Many export markets – particularly in Europe, the US, and Middle East – require 
suppliers to submit WVTR test data as part of material qualification. Pharmaceutical
packaging exported to regulated markets must meet ICH Q1A stability guidelines, 
which specify temperature and humidity conditions for packaging material testing.

Need a WVTR tester for your lab?

Flexitest supplies Labthink permeability testing instruments across India  gravimetric,
IR sensor, electrolytic, and combo models.

## NABL-traceable calibration

## Free installation & demo

## 24/7 online support

 [     Explore Permeability Testing Instruments   ](https://flexitest.in/blogs/blog-what-is-wvtr-testing-guide-packaging-engineers/#elementor-action%3Aaction%3Dpopup%3Aopen%26settings%3DeyJpZCI6IjE0NDQ4IiwidG9nZ2xlIjpmYWxzZX0%3D)

or email[info@flexitest.in ](https://flexitest.in/blogs/blog-what-is-wvtr-testing-guide-packaging-engineers/info@flexitest.in)·
www.flexitest.in

## Recent Post

[ ⌊Salt Spray Chamber A Complete Guide to Salt Spray Corrosion Testing⌉ ](https://flexitest.in/blogs/salt-spray-chamber-guide/)

## 󠀁[Salt Spray Chamber: A Complete Guide to Salt Spray Corrosion Testing](https://flexitest.in/blogs/salt-spray-chamber-guide/)󠁿

How a salt spray chamber works, the ASTM B117 and ISO 9227 standards, which industries
use it and how to...

[Read More](https://flexitest.in/blogs/salt-spray-chamber-guide/)

[ ⌊HDPE PP Woven Sack Testing BIS Requirements and Choosing the Right UTM⌉ ](https://flexitest.in/blogs/hdpe-pp-woven-sack-testing-bis-utm-selection/)

## 󠀁[HDPE & PP Woven Sack Testing: BIS Requirements and Choosing the Right UTM](https://flexitest.in/blogs/hdpe-pp-woven-sack-testing-bis-utm-selection/)󠁿

Review BIS woven-sack requirements, fabric and seam testing, and verified Tinius
Olsen 5ST and 25ST specifications for your HDPE or...

[Read More](https://flexitest.in/blogs/hdpe-pp-woven-sack-testing-bis-utm-selection/)

[ ⌊Capillary Flow Porometry A Complete Guide to How It Works Methods Applications⌉ ](https://flexitest.in/blogs/air-permeability-tester-fx-3300-labair-iv-guide/)

## 󠀁[Air Permeability Tester for Technical Textiles: A Complete Guide to the FX 3300 LabAir IV](https://flexitest.in/blogs/air-permeability-tester-fx-3300-labair-iv-guide/)󠁿

What air permeability is, why it matters for airbags, filters and technical textiles,
how it is tested, and a close...

[Read More](https://flexitest.in/blogs/air-permeability-tester-fx-3300-labair-iv-guide/)

[ ⌊Coefficient of Friction Tester: What It is, Why It Matters, and How to Choose the Right One — weighted sled pulled across plastic packaging film on a friction tester bed⌉ ](https://flexitest.in/blogs/coefficient-of-friction-tester-selection-guide/)

## 󠀁[Coefficient of Friction Tester: What It is, Why It Matters, and How to Choose the Right One](https://flexitest.in/blogs/coefficient-of-friction-tester-selection-guide/)󠁿

Learn how coefficient of friction testing supports packaging performance, compare
C620H and MXD-02 testers, and choose a configuration for your...

[Read More](https://flexitest.in/blogs/coefficient-of-friction-tester-selection-guide/)