# Development of Integral Package Barrier Property Testing

 1. [Home](https://flexitest.in)
 2. [Blog](https://flexitest.in/category/blog/)
 3. Development of Integral Package Barrier Property Testing

In the past, barrier property testing was only for films, which has brought great
inconvenience to end package manufacturers and users. Most raw materials they bought
could make barrier property testing, but the finished packages, owing to the lack
of testing techniques, would bring hidden dangers to end-product quality. The difficulty
for testing lies in the varied shapes of packages. However, owing to the promotion
of barrier property testing, integral package barrier property testing has made 
great progress with more kinds of testable packages. This article makes a detailed
introduction on the development of integral package barrier property testing and
relevant testing cases.

## 1. Introduction to Integral Package Barrier Property Testing Techniques

Keeping certain shapes is the most basic characteristic for packages. Therefore,
keeping the package intact is the first thing when testing. Secondly, the seal performance
of testing instruments and sampling accessories should be guaranteed. Those two 
points are difficult to achieve for package testing, compared with film and sheet
testing.

## 1.1 Equal Pressure Method Package Oxygen Transmission Rate Testing Techniques

The testing principles of equal pressure method oxygen transmission rate for both
films and packages are similar. First, the preconditioned specimen separates the
transmission chamber into two separate gas flow systems. Testing gas flows in one
side of the package, such as pure oxygen or mixed gas with oxygen; high pure carrier
gas flows in the other side. Though the gas pressure of two sides are the same, 
oxygen sub-pressures are different. Therefore, under the gradient of oxygen concentration,
oxygen transmits through package and is carried to the sensor by the carrier gas.
The sensor will measure the oxygen quantity in the carrier gas flow precisely, so
as to work out the oxygen transmission rate of the tested package. If only specimen
preparation issue can be effectively resolved, various packages are testable by 
this method. Testing subjects can be the integral package or a part of it, including
various bottles, the connecting part of bottle cup and bottle body, bottle cup, 
capsule, blister, tube, injection, IV bags, flexible pipe and various ball-shape
packages. Besides, the contents of tested packages can be in or not, so as to provide
most reliable data for package evaluation in actual application and quality change
of contents.

At present, ASTM F 1307 is the only testing standard for equal pressure method, 
and is applicable for all packages that can produce dry spaces inside. Moreover,
equal pressure method oxygen transmission rate testing techniques can also be used
under humid circumstances, and can further provide an environment with certain humidity
in or out side the package.

## 1.2 Differential Pressure Method Package Gas Transmission Rate Testing Technique

Keeping the package shape intact is the main difficulty for differential pressure
method package gas transmission rate testing. Owing to the pressure difference between
the inner and outside of the package, the tested specimen might be destroyed by 
pressure difference without appropriate means to keep its shape, and result in meaningless
testing results, or even no testing data. At present, in the field of differential
pressure method gas transmission rate testing research, Labthink has made breakthrough.
At the same time, Labthink has successfully extended integral package gas transmission
rate testing from oxygen alone to many common inorganic gases. However, there are
not many kinds of subjects can be tested with this method.

## 1.3 Weighing Method Package Water Vapor Transmission Rate Testing Technique

Weighing method water vapor transmission rate testing is the traditional method 
for package water vapor transmission rate testing; the relevant testing methods 
are: GB/T 6981-1986, GB/T 6982-1986 and ASTM D 3079-94. The testing process is as
follows: first, put the desiccant (container is permitted) into the specimen, and
seal the open place on the package wall. After preheating, put the specimen into
the testing chamber with constant humidity and constant temperature for humidity
and temperature test. Then, weigh the weight of the specimen at proper intervals
according to the water vapor transmission performance of the package. When the transmission
reaches stability, calculate the integral package water vapor transmission rate 
on the added weight of the specimen. However, open a mouth on the package wall is
not practical, and it would always lead to operational failure and corresponding
failure. Therefore, in the standards for pharmaceutical packaging materials, the
desiccant is changed into distilled water or other testing solvents when using this
method. Thus, there is no need to open and close the package mouth repeatedly; and
the only thing needs to do is to weigh the package at certain intervals. However,
the long testing periods and precision limit are the inherent shortcomings of this
method.

## 1.4 Sensor Method Package Water Vapor Transmission Rate Testing Technique

Sensor method and different pressure method package water vapor transmission rate
testing techniques are similar in the testing principle: separate the transmission
cell into two isolated gas flow system by the package, one side of the package flows
the carrier gas (dry); and another side is in a relative humidity. Thus, a stable
water vapor concentration difference exists between the two sides of the specimen(
relative humidity). Under the influence of water vapor concentration difference,
water vapor transmits through the package wall and is carried to the sensor. The
sensor measures the water vapor content in the carrier gas accurately so as to further
calculate water vapor transmission rate of the specimen. This method is applicable
for bottles, pouches, capsules, blisters, IV packages, flexible pipes and other 
forms of packages. Now, the testing accuracy of this method is up to 0.001g/pkg·d;
the testing period is only 3 to 4 days; and the testing process is completely automatic.

## 2. Typical Application Examples

Usually, package barrier property testing is for bottles or certain parts of the
bottle. However, package is not limited to bottle, pouches, flexible pipe and PVC
trays also have broad applications, among which, the testing for pouches and small-
sized package (e.g., blister) are more emphasized.

## 2.1 Pouches

The space maintenance of the pouches should be taken care of when using equal pressure
method or sensor method. As to pouches, if the pressures inside and outside can 
not be well controlled, it would result in less gas transmission area and lead to
data error. Therefore, the pouches should be bulged during precondition period, 
and it can be achieved by putting certain quantities of gas or other accessories
into the pouches. At the same time, the space inside pouches should also be kept
during testing process so as to avoid shriveling, especially for thin food pouches.
As to IV bags, jelly pouches, stand up pouches and other thick pouches, their shriveling
probability is less.

When using weighing method, how to keep the space inside the pouches is also a problem.
Meanwhile, how to seal pouches after filling distilled water inside should also 
be considered, which increase the difficulty in actual operation.

## 2.2 Blisters

Blisters are usually of small volume. Therefore, they can only be tested by equal
pressure method or sensor method. Furthermore, the specimen preparation can only
be accomplished with customized accessories. Meanwhile, the adjustment of flowing
speed during testing process should also be cautious so as to avoid sudden pressure
increase and decrease caused by violent change of gas quantity, and thus, avoid 
influences to the specimen status.

Usually, the testing accessories for blisters are also applicable for small-sized
package testing, such as capsule; and can expand to more kinds of small-sized packages
conveniently.

## 3. Conclusions

The development of integral package barrier property testing techniques has greatly
expanded the scope of barrier property testing. Now, the testing subjects have expanded
to nearly all the packages, which have brought fundamental testing reform for package
manufacturers and users. Meanwhile, with the leak and seal testing as well as headspace
gas analysis, a more integral, effective and accurate package result can be guaranteed.

## Recent Post

[ ⌊IS 11652 UV Weathering Test for Cement Sacks 1⌉ ](https://flexitest.in/blogs/is-11652-uv-weathering-test-cement-sacks/)

## 󠀁[IS 11652 UV Weathering Test for Cement Sacks](https://flexitest.in/blogs/is-11652-uv-weathering-test-cement-sacks/)󠁿

 October 28, 2026

[ ⌊Salt Spray Chamber A Complete Guide to Salt Spray Corrosion Testing 1⌉ ](https://flexitest.in/blogs/salt-spray-chamber-guide/)

## 󠀁[Salt Spray Chamber: A Complete Guide to Salt Spray Corrosion Testing](https://flexitest.in/blogs/salt-spray-chamber-guide/)󠁿

 October 12, 2026

[ ⌊HDPE PP Woven Sack Testing BIS Requirements and Choosing the Right UTM⌉ ](https://flexitest.in/blogs/hdpe-pp-woven-sack-testing-bis-utm-selection/)

## 󠀁[HDPE & PP Woven Sack Testing: BIS Requirements and Choosing the Right UTM](https://flexitest.in/blogs/hdpe-pp-woven-sack-testing-bis-utm-selection/)󠁿

 October 8, 2026

[ ⌊Air Permeability Tester for Technical Textiles A Complete Guide to the FX 3300 LabAir IV 1⌉ ](https://flexitest.in/blogs/air-permeability-tester-fx-3300-labair-iv-guide/)

## 󠀁[Air Permeability Tester for Technical Textiles: A Complete Guide to the FX 3300 LabAir IV](https://flexitest.in/blogs/air-permeability-tester-fx-3300-labair-iv-guide/)󠁿

 September 30, 2026