# Map Headspace Gas Tester

- Link: https://flexitest.in/packaging-testing-equipments/map-headspace-gas-test/
- Published: 2024-11-15T05:04:02+05:30
- Author: chetanvarne

# Map Headspace Gas Tester

 1. [Home](https://flexitest.in)
 2. [Packaging Testing Equipments](https://flexitest.in/packaging-testing-equipments/)
 3. Map Headspace Gas Tester

![C650H and C650M headspace gas analysers](https://flexitest.in/wp-content/uploads/
2025/04/C650H-C650M-Packaging-main-banner-new-2-compressed-scaled-1.webp "Map Headspace
Gas Tester 13")

![C650H and C650M headspace gas analysers](https://flexitest.in/wp-content/uploads/
2026/09/c650h_c650m_packaging_main_banner_new_mobile-1024x1004.webp "Map Headspace
Gas Tester 14")

##  Ensure Freshness with  Advanced Headspace Gas Testing!

It is a type of method used to analyse the composition of gases present within the
headspace (air space) of a sealed package. This tester is commonly used in the food
packaging industry to ensure the quality and safety of perishable products. MAP 
headspace gas testing, facilitated by instruments like headspace gas analyzers, 
is a crucial quality control measure in industries such as food packaging, pharmaceuticals,
and cosmetics. It ensures product freshness, shelf life, and safety by monitoring
and optimising the atmosphere within sealed packages.

##  Headspace Gas   Analyzer C650H

![Headspace Gas Analyzer C650H](https://flexitest.in/wp-content/uploads/2025/04/
C650H-Packaging-product-banner-new-scaled.webp "Map Headspace Gas Tester 15")

![Headspace Gas Analyzer C650H](https://flexitest.in/wp-content/uploads/2026/09/
c650h_packaging_main_banner_new_mobile-1024x1004.webp "Map Headspace Gas Tester 
16")

The C650H Headspace Gas Analyzer is used in the packaging industry to measure the
levels of gases like oxygen and carbon dioxide within sealed packages. This ensures
product freshness, quality, and extended shelf life by verifying that the packaging
maintains the correct atmosphere to preserve the contents.

 Get Instant Quote

####  Submit Your Details to Download Brochure!

  Name

  Email

  Phone Number

  Company Name

  Company Location

   By clicking the button, I agree and consent to the company’s [Privacy Policy](https://flexitest.in/privacy-policy)

![C650H headspace gas analyser in a packaging laboratory](https://flexitest.in/wp-
content/uploads/2025/04/C650H-Packaging-inner-bg-min-scaled-e1747226258132.webp "
Map Headspace Gas Tester 17")

 image-1

 Thermal-printer-2

 LED-Display

## Features

 *     The instrument is controlled by micro-computer, which can analyse, process
   and transfer the test data and test report
 *     The built-in data storage function allows it to store a large amount of test
   data.
 *     Portable design allows operating the instrument in a laboratory or on a production
   site.
 *     Equipped with standard RS232 ports and professional software for convenient
   PC connection and data transfer

 Get Free Quote

## Headspace Gas Analyzer C650M

![Headspace Gas Analyzer C650M](https://flexitest.in/wp-content/uploads/2025/04/
C650M-Packaging-product-banner-new-2-2048x784-1.webp "Map Headspace Gas Tester 18")

![Headspace Gas Analyzer C650M](https://flexitest.in/wp-content/uploads/2026/09/
c650m_packaging_main_banner_new_mobile-1024x1004.webp "Map Headspace Gas Tester 
19")

![C650M headspace gas analyser in a packaging laboratory](https://flexitest.in/wp-
content/uploads/2025/04/C650M-Packaging-inner-bg-compressed-scaled-1-e1747226103871.
webp "Map Headspace Gas Tester 20")

The C650M Headspace Gas Analyzer is integral to the packaging industry for assessing
gas composition within sealed packages. By precisely measuring oxygen, carbon dioxide,
and other gases, it ensures optimal conditions for product preservation, shelf life
extension, and quality maintenance, crucial for food, pharmaceuticals, etc.

 Get Instant Quote

####  Submit Your Details to Download Brochure!

  Name

  Email

  Phone Number

  Company Name

  Company Location

   By clicking the button, I agree and consent to the company’s [Privacy Policy](https://flexitest.in/privacy-policy)

 Test-Results-2

 Test-Applications-3

 headspace-of-Packaging-food-containers

## Features

 *     Handheld and portable design, easy-to-operate with one hand, suitable for
   tests on production line
 *     Auto shutdown for energy saving
 *     One-button calibration, simple and efficient
 *     Components and parts are supplied by global well-known manufacturers, which
   guarantee stable performance of the instrument
 *     Protective cover for sampling probe to ensure the safety of the operator
 *     Embedded gas sensors for accurate analysis of the gas contents inside flexible
   or rigid packages
 *     Embedded pressure sensor for accurate determination of the vacuum degree 
   inside the package
 *     CO2 sensor uses NDIR technology, patented solid state LED, detector and gold-
   plated optic components

 Get Free Quote

## Select the right product for your  specific requirements

Compare Labthink headspace gas analyzer models by measurement range, accuracy, sampling
volume, and form factor.

 ← Swipe to see full table →

 Headspace Gas Analyzer: C650H vs C650M  |  Specification |  Unit |  C650H |  C650M |  
    | General | 
 |  Form factor |   |  Benchtop |  Handheld / Portable |  
 |  Display |   |  LCD, menu interface |  Industrial touch screen (CN / EN) |  
 |  Data storage |   |  Built-in |  Up to 1,200 results |  
 |  Output / Interface |   |  RS232 + micro printer |  Auto storage, power-failure memory |  
 |  Standard compliance |   |  ASTM F2714 |  ASTM F2714 |  
  | O₂ Measurement | 
 |  O₂ test principle |   |  Fluorescent decay |  Electrochemistry |  
 |  O₂ measurement range |  % |  0.2 – 21 |  0 – 100 |  
 |  O₂ accuracy |  % |  ±0.2 |  ±0.2 |  
 |  O₂ resolution |  % |  — |  0.01 |  
 |  O₂ sensor life |   |  — |  ~2 years (in air) |  
 |  O₂ sampling volume |  mL |  ≥ 5 |  < 2 (std mode) |  
  | CO₂ Measurement (Optional) | 
 |  CO₂ test principle |   |  NDIR (infrared) |  Infrared absorption |  
 |  CO₂ measurement range |  % |  2 – 100 |  0 – 100 |  
 |  CO₂ accuracy |   |  ±2% |  ±(0.03% + 5% of reading) |  
 |  CO₂ resolution |  % |  — |  0.01 |  
 |  CO₂ sensor life |   |  — |  > 15 years |  
 |  CO₂ sampling volume |  mL |  ≥ 20 |  15 (std mode) |  
  | Physical | 
 |  Dimensions (L × W × H) |  mm |  350 × 330 × 200 |  220 × 110 × 70 |  
 |  Net weight |  kg |  5.5 |  0.6 |  
  | Electrical | 
 |  Power supply |   |  220 VAC 50 Hz / 120 VAC 60 Hz |  220 VAC ±10% 50 Hz / 120 VAC ±10% 60 Hz |

* CO₂ measurement is optional on both models. Specifications are nominal and subject
to final configuration.

General

Form factor

Benchtop

Display

LCD, menu interface

Data storage

Built-in

Interface

RS232 + micro printer

Standard

ASTM F2714

O₂ Measurement

Principle

Fluorescent decay

Range

0.2 – 21%

Accuracy

±0.2%

Sampling volume

≥ 5 mL

CO₂ Measurement (Optional)

Principle

NDIR (infrared)

Range

2 – 100%

Accuracy

±2%

Sampling volume

≥ 20 mL

Physical & Electrical

Dimensions (L×W×H)

350 × 330 × 200 mm

Net weight

5.5 kg

Power supply

220 VAC 50 Hz / 120 VAC 60 Hz

General

Form factor

Handheld / Portable

Display

Industrial touch screen (CN/EN)

Data storage

Up to 1,200 results

Interface

Auto storage, power-failure memory

Standard

ASTM F2714

O₂ Measurement

Principle

Electrochemistry

Range

0 – 100%

Accuracy

±0.2%

Resolution

0.01%

Sensor life

~2 years (in air)

Sampling volume

< 2 mL (std mode)

CO₂ Measurement (Optional)

Principle

Infrared absorption

Range

0 – 100%

Accuracy

±(0.03% + 5% of reading)

Resolution

0.01%

Sensor life

> 15 years

Sampling volume

15 mL (std mode)

Physical & Electrical

Dimensions (L×W×H)

220 × 110 × 70 mm

Net weight

0.6 kg

Power supply

220 VAC ±10% 50 Hz / 120 VAC ±10% 60 Hz

* CO₂ measurement is optional on both models.

# FAQ's

 Frequently Asked Questions – MAP Headspace Gas Testing 

  What is MAP headspace gas testing and why is it important for packaging?

MAP (Modified Atmosphere Packaging) headspace gas testing measures the concentration
of oxygen and carbon dioxide inside sealed packages. It verifies that the correct
gas mixture was introduced during packaging. Accurate headspace analysis per ASTM
F2714 is essential for food, pharmaceutical, and medical device manufacturers to
confirm shelf life, prevent spoilage, and ensure product safety throughout the supply
chain.

  Which gases are measured during MAP headspace gas analysis?

MAP headspace gas analysis primarily measures oxygen (O2) and carbon dioxide (CO2)
concentrations inside sealed packages. Oxygen levels are measured per ASTM F2714
using fluorescent decay technology. Controlling O2 below critical thresholds prevents
oxidation and microbial growth, while CO2 inhibits bacterial activity. Nitrogen (
N2) is also used as a filler gas to displace oxygen in MAP food and pharmaceutical
packaging.

  What is the ASTM F2714 standard and how does it apply to headspace gas testing?

ASTM F2714 is the standard test method for oxygen headspace analysis of sealed packages
using fluorescent decay. It applies directly to MAP packaging where the oxygen content
of the headspace determines the protection provided by barrier materials. Testing
per ASTM F2714 measures residual oxygen in closed packages, supports package permeability
studies, and helps manufacturers validate shelf life for food, chemical, and pharmaceutical
products.

  What is the difference between destructive and non-destructive headspace gas testing?

Destructive headspace testing, as covered by ASTM F2095, involves piercing or pressurising
the package to measure gas composition or detect leaks — the tested package cannot
be reused. Non-destructive methods per ASTM F2338 use vacuum decay or fluorescent
sensors to detect leaks without damaging the package. For production line quality
control, non-destructive methods allow larger sampling without product loss, while
destructive methods are used for detailed laboratory validation.

  What is ASTM F2095 and when is it used in MAP packaging quality control?

ASTM F2095 covers pressure decay leak testing for flexible packages including nonporous
film, foil, and laminate pouches and foil-sealed trays. It is used to detect seal
failures and micro-leaks in MAP packaging that could allow oxygen ingress and compromise
product shelf life. When testing medical packaging that must conform to ISO 11607
standards, ASTM F2095 pressure decay results may need to be verified with additional
integrity test methods.

  How does a MAP headspace gas analyser work in practice?

A MAP headspace gas analyser uses a hollow needle probe inserted through the package
film to extract a micro-sample of headspace gas. Sensors — typically electrochemical
for O2 and infrared (NDIR) for CO2 — measure gas concentrations in seconds. Testing
follows ASTM F2714 for oxygen analysis. Results are displayed as percentage concentrations,
allowing operators to verify correct gas flushing, detect seal failures, and confirm
compliance with product-specific MAP specifications.

  Which industries use MAP headspace gas testing equipment?

MAP headspace gas testing is used across food packaging (meat, seafood, dairy, bakery,
produce), pharmaceutical packaging (blister packs, vials, ampoules), and medical
device packaging (sterile barrier systems per ISO 11607). It is also used in nutraceutical
packaging, coffee packaging with one-way valves, and specialty chemical packaging
where oxygen and moisture control are critical for maintaining product quality and
regulatory compliance.

  How is headspace gas testing used for pharmaceutical and medical device packaging?

In pharmaceutical and medical device packaging, headspace gas testing verifies residual
oxygen levels to ensure product stability and sterility. ISO 11607 requires that
sterile barrier packaging systems maintain integrity through their claimed shelf
life. Headspace analysis per ASTM F2714 supports shelf life validation studies, 
and leak testing per ASTM F2095 provides physical evidence of package integrity —
both required for FDA and regulatory submissions.

  How often should MAP headspace gas testing be performed on a production line?

Testing frequency depends on production volume, risk level, and regulatory requirements.
Most food and pharmaceutical manufacturers perform headspace gas analysis on a statistical
sampling basis — typically one package per batch or per defined production interval.
For high-risk products such as sterile medical devices or injectable pharmaceutical
packaging under ISO 11607, more rigorous sampling plans are required, with results
documented as part of process validation and quality management records per ISO 
17025.

  How should a MAP headspace gas analyser be calibrated and maintained?

MAP headspace gas analysers must be calibrated regularly using certified reference
gas mixtures traceable to national standards to ensure measurement accuracy. Calibration
records must be maintained per ISO 17025 requirements for laboratory competence.
Sensors — electrochemical O2 sensors and infrared CO2 sensors — have defined operational
lifespans and must be replaced as per the manufacturer’s schedule. Regular calibration
ensures compliance with ASTM F2714 and maintains traceability for regulatory submissions.

 { "@context": "https://schema.org", "@type": "FAQPage", "mainEntity": [ { "@type":"
Question", "name": "What is MAP headspace gas testing and why is it important for
packaging?", "acceptedAnswer": { "@type": "Answer", "text": "MAP (Modified Atmosphere
Packaging) headspace gas testing measures the concentration of oxygen and carbon
dioxide inside sealed packages. It verifies that the correct gas mixture was introduced
during packaging. Accurate headspace analysis per ASTM F2714 is essential for food,
pharmaceutical, and medical device manufacturers to confirm shelf life, prevent 
spoilage, and ensure product safety throughout the supply chain." } }, { "@type":"
Question", "name": "Which gases are measured during MAP headspace gas analysis?","
acceptedAnswer": { "@type": "Answer", "text": "MAP headspace gas analysis primarily
measures oxygen (O2) and carbon dioxide (CO2) concentrations inside sealed packages.
Oxygen levels are measured per ASTM F2714 using fluorescent decay technology. Controlling
O2 below critical thresholds prevents oxidation and microbial growth, while CO2 
inhibits bacterial activity. Nitrogen (N2) is also used as a filler gas to displace
oxygen in MAP food and pharmaceutical packaging." } }, { "@type": "Question", "name":"
What is the ASTM F2714 standard and how does it apply to headspace gas testing?","
acceptedAnswer": { "@type": "Answer", "text": "ASTM F2714 is the standard test method
for oxygen headspace analysis of sealed packages using fluorescent decay. It applies
directly to MAP packaging where the oxygen content of the headspace determines the
protection provided by barrier materials. Testing per ASTM F2714 measures residual
oxygen in closed packages, supports package permeability studies, and helps manufacturers
validate shelf life for food, chemical, and pharmaceutical products." } }, { "@type":"
Question", "name": "What is the difference between destructive and non-destructive
headspace gas testing?", "acceptedAnswer": { "@type": "Answer", "text": "Destructive
headspace testing, as covered by ASTM F2095, involves piercing or pressurising the
package to measure gas composition or detect leaks — the tested package cannot be
reused. Non-destructive methods per ASTM F2338 use vacuum decay or fluorescent sensors
to detect leaks without damaging the package. For production line quality control,
non-destructive methods allow larger sampling without product loss, while destructive
methods are used for detailed laboratory validation." } }, { "@type": "Question","
name": "What is ASTM F2095 and when is it used in MAP packaging quality control?","
acceptedAnswer": { "@type": "Answer", "text": "ASTM F2095 covers pressure decay 
leak testing for flexible packages including nonporous film, foil, and laminate 
pouches and foil-sealed trays. It is used to detect seal failures and micro-leaks
in MAP packaging that could allow oxygen ingress and compromise product shelf life.
When testing medical packaging that must conform to ISO 11607 standards, ASTM F2095
pressure decay results may need to be verified with additional integrity test methods."}},{"@
type": "Question", "name": "How does a MAP headspace gas analyser work in practice?","
acceptedAnswer": { "@type": "Answer", "text": "A MAP headspace gas analyser uses
a hollow needle probe inserted through the package film to extract a micro-sample
of headspace gas. Sensors — typically electrochemical for O2 and infrared (NDIR)
for CO2 — measure gas concentrations in seconds. Testing follows ASTM F2714 for 
oxygen analysis. Results are displayed as percentage concentrations, allowing operators
to verify correct gas flushing, detect seal failures, and confirm compliance with
product-specific MAP specifications." } }, { "@type": "Question", "name": "Which
industries use MAP headspace gas testing equipment?", "acceptedAnswer": { "@type":"
Answer", "text": "MAP headspace gas testing is used across food packaging (meat,
seafood, dairy, bakery, produce), pharmaceutical packaging (blister packs, vials,
ampoules), and medical device packaging (sterile barrier systems per ISO 11607).
It is also used in nutraceutical packaging, coffee packaging with one-way valves,
and specialty chemical packaging where oxygen and moisture control are critical 
for maintaining product quality and regulatory compliance." } }, { "@type": "Question","
name": "How is headspace gas testing used for pharmaceutical and medical device 
packaging?", "acceptedAnswer": { "@type": "Answer", "text": "In pharmaceutical and
medical device packaging, headspace gas testing verifies residual oxygen levels 
to ensure product stability and sterility. ISO 11607 requires that sterile barrier
packaging systems maintain integrity through their claimed shelf life. Headspace
analysis per ASTM F2714 supports shelf life validation studies, and leak testing
per ASTM F2095 provides physical evidence of package integrity — both required for
FDA and regulatory submissions." } }, { "@type": "Question", "name": "How often 
should MAP headspace gas testing be performed on a production line?", "acceptedAnswer":{"@
type": "Answer", "text": "Testing frequency depends on production volume, risk level,
and regulatory requirements. Most food and pharmaceutical manufacturers perform 
headspace gas analysis on a statistical sampling basis — typically one package per
batch or per defined production interval. For high-risk products such as sterile
medical devices or injectable pharmaceutical packaging under ISO 11607, more rigorous
sampling plans are required, with results documented as part of process validation
and quality management records per ISO 17025." } }, { "@type": "Question", "name":"
How should a MAP headspace gas analyser be calibrated and maintained?", "acceptedAnswer":{"@
type": "Answer", "text": "MAP headspace gas analysers must be calibrated regularly
using certified reference gas mixtures traceable to national standards to ensure
measurement accuracy. Calibration records must be maintained per ISO 17025 requirements
for laboratory competence. Sensors — electrochemical O2 sensors and infrared CO2
sensors — have defined operational lifespans and must be replaced as per the manufacturer's
schedule. Regular calibration ensures compliance with ASTM F2714 and maintains traceability
for regulatory submissions." } } ] }

## Related Machines

[⌊Halogen Moisture Analyser⌉⌊Halogen Moisture Analyser⌉[

[Halogen Moisture Analyser](https://flexitest.in/packaging-testing-equipments/moisture-analyser/)

Buy Sartorius MA160 & MA100 halogen moisture analysers in India. Accurate loss-on-
drying testing for packaging, plastics and pharma, with free installation.

[View Details ](https://flexitest.in/packaging-testing-equipments/moisture-analyser/)

[⌊Drying and Heating Chambers Model M115⌉⌊Drying and Heating Chambers Model M115⌉[

[Drying and Heating Chambers Model M115](https://flexitest.in/packaging-testing-equipments/drying-and-heating-chambers-model-m115/)

BINDER M115 drying and heating chamber, 115 litre, for conditioning and drying packaging
samples before mechanical or barrier testing.

[View Details ](https://flexitest.in/packaging-testing-equipments/drying-and-heating-chambers-model-m115/)

[⌊Vacuum Drying Chambers Model VD 56⌉⌊Vacuum Drying Chambers Model VD 56⌉[

[Vacuum Drying Chambers Model VD 56](https://flexitest.in/packaging-testing-equipments/drying-heating-chambers/drying-and-heating-chamber-model-vd-56/)

BINDER VD 56 vacuum drying chamber, 56 litre, for gentle low-temperature drying 
of heat-sensitive packaging samples and residues.

[View Details ](https://flexitest.in/packaging-testing-equipments/drying-heating-chambers/drying-and-heating-chamber-model-vd-56/)

[⌊Accelerated Weathering Chamber – Packaging⌉⌊Accelerated Weathering Chamber – Packaging⌉[

[Accelerated Weathering Chamber – Packaging](https://flexitest.in/packaging-testing-equipments/accelerated-weathering-chamber-packaging/)

UV and xenon accelerated weathering chambers that replicate sunlight, heat and moisture
so packaging materials are proven before launch.

[View Details ](https://flexitest.in/packaging-testing-equipments/accelerated-weathering-chamber-packaging/)
