# Melt Flow Indexer

- Link: https://flexitest.in/packaging-testing-equipments/melt-flow-index/
- Published: 2024-11-15T06:00:36+05:30
- Author: kamal

# Melt Flow Indexer

 1. [Home](https://flexitest.in)
 2. [Packaging Testing Equipments](https://flexitest.in/packaging-testing-equipments/)
 3. Melt Flow Indexer

## Precision Measurement for  Superior Packaging Performance

 Melt Flow Indexer (MFI) is a vital instrument in the packaging industry, used to
determine the flow rate of thermoplastic polymers. By accurately measuring how polymers
behave under heat and pressure, the MFI helps manufacturers ensure the quality, 
consistency, and suitability of materials for diverse packaging applications. This
assessment is essential for optimising production processes and achieving the desired
characteristics in finished products, from films to rigid containers.

## MP 1200 Melt Flow   Melt Flow Index

![Tinius Olsen MP 1200 melt flow indexer beside colourful plastic resin pellets](
https://flexitest.in/wp-content/uploads/2025/04/MP1200-Packaging-product-banner-
new-compressed-scaled-1.webp "Melt Flow Indexer 5")

![Tinius Olsen MP 1200 Melt Flow Indexer equipment shown alongside colorful plastic
resin pellets](https://flexitest.in/wp-content/uploads/2026/09/mp1200_packaging_banner_new.
webp "Melt Flow Indexer 6")

![MP1200 Packaging inner bg compressed scaled min e1747225620706](https://flexitest.
in/wp-content/uploads/2025/04/MP1200-Packaging-inner-bg-compressed-scaled-min-e1747225620706.
webp "Melt Flow Indexer 7")

MP1200 is an advanced melt flow tester that integrates the latest in melt flow measurement
technology, designed to simplify and enhance polymer testing across various industries,
including packaging, automotive, and more. Built to comply with international standards
such as ASTM D1238 and ISO 1133-1 & 2, the MP1200 ensures accurate, repeatable, 
and reliable results, providing critical data for quality control and material selection.

 Get Instant Quote

####  Submit Your Details to Download Brochure!

  Name

  Email

  Phone Number

  Company Name

  Company Location

   By clicking the button, I agree and consent to the company’s [Privacy Policy](https://flexitest.in/privacy-policy)

 Single-or-multiple-MFI-Unit-capability

 Mannual-Automatic-cutter-quick-die-release

 Traceable-Certified-weights-Auto-Loaded-to-test

 Heated-barrel-with-PID-Zone-Control

 Piston-Diplacement-Transducer-enables-Procedure-B-Testing

 Touch-Screen-easy-programme-selection

## Features

 *     Three-zone band heater.
 *     Touch-screen control.
 *     Quick die release.
 *     Powerful data analysis and control software.
 *     USB connectivity.
 *     Tapered weight design

 Get Free Quote

## Melt Flow Index : The flow of quality in packaging

Models:

![MP 1200 unit](https://flexitest.in/wp-content/uploads/2025/04/MP-1200-e1745826378127.
webp "Melt Flow Indexer 8")

## MP 1200

  |  Conformance |  ASTM D1238 and D3364, ISO 1133-1 and -2, BS2782, DIN 53735, JIS K7210 |  
 |  Operating temperature |  410°C max |  
 |  Temperature control |  +/- 0.1°C |  
 |  Spatial temperature variation |  +/- 0.1°C |  
 |  Temperature controller |  Three zone PID |  
 |  Temperature sensors |  Platinum RTDs (3) |  
 |  Timer resolution |

Displayed capture time0.01 second

  |  
 |

Internal timing interval0.001 second

  |  
 |  Display |  7.1” LCD touchscreen, 800 x 480 resolution |  
 |  Data entry |  Touchscreen display |  
 |  Communications port |  USB |  
 |  Weights |  Stainless steel or Aluminum, +/- 0.5% tolerance |  
 | PPDT-1200 actuating switch | 
 |  Transducer accuracy |  +/- 0.001in(ASTM)
+/- 0.02mm(ISO) |  
 | MWLD-1200 motorised weight support | 
 |  Transducer accuracy |  +/- 0.1mm (+/- 0.01in) |  
 | Physical | 
 |  Overall dimensions (WxDxH) |  458mm/18in x 394mm/15.5in x 521mm/20.5in high for basic unit or 762mm/30in for motorised unit (to top of weight cage, platform lowered) |  
 |  Net weight |  21kg/46lb for basic unit or 32kg/71lb for motorised unit, not including weights or options |  
 |  Gross weight |  32kg/70lb for basic unit or 43kg/95lb for motorised unit, not including weights or options |

FAQ's

Frequently Asked Questions – Melt Flow Index Testing

  What is a Melt Flow Index tester and why is it used in packaging material testing?

A Melt Flow Index (MFI) tester measures the flow rate of molten thermoplastic polymer
through a standardised die under defined temperature and load conditions. It evaluates
the processability, viscosity, and molecular weight consistency of plastics used
in packaging. Per ASTM D1238 and ISO 1133-1, MFI testing is essential for incoming
raw material inspection, lot-to-lot consistency verification, and quality control
of polyethylene, polypropylene, and other thermoplastics used in packaging films
and containers.

  What is ASTM D1238 and how is it used for packaging plastic testing?

ASTM D1238 is the Standard Test Method for Melt Flow Rates of Thermoplastics by 
Extrusion Plastometer. The latest version ASTM D1238:2023 defines the use of force-
controlled extrusion plastometers for the determination of melt mass-flow rate (
MFR) and melt volume-flow rate (MVR). It is widely used in packaging to verify that
PE, PP, and other thermoplastic packaging materials meet specified flow rate requirements
before production, ensuring consistent film quality and processability on extrusion
and lamination lines.

  What is ISO 1133-1 and what does it measure for thermoplastic packaging materials?

ISO 1133-1:2022 specifies two procedures for the determination of the melt mass-
flow rate (MFR) and the melt volume-flow rate (MVR) of thermoplastic materials under
specified conditions of temperature and load. Procedure A is a mass-measurement 
method. Procedure B is a displacement-measurement method. Both procedures are used
primarily for quality control of packaging plastics including HDPE, LDPE, LLDPE,
and PP — the primary materials used in flexible and rigid packaging manufacturing.

  What is the difference between ASTM D1238 and ISO 1133-1 for melt flow testing?

The methods for melt flow index testing to ASTM D1238 and ISO 1133 on thermoplastics
are equivalent but not identical, as they differ in some respects, especially in
terms of test procedure. In ASTM D1238, the duration of the preheating phase is 
standardised at 7±0.5 minutes with very strict tolerance; in ISO 1133-1 it is specified
to at least 5 minutes, but can also be significantly longer. For packaging laboratories
in India, ASTM D1238 is typically specified by North American buyers while ISO 1133-
1 is required for European and international market compliance

  What is the difference between MFI, MFR, and MVR in melt flow testing?

MFI (Melt Flow Index) is the older term used predominantly in North America per 
ASTM D1238. MFR (Melt Flow Rate) is the ISO 1133 term used in international standards.
They describe the same measurement — grams of polymer extruded through a standardised
die per 10 minutes under defined conditions. MVR (Melt Volume-Flow Rate) measures
volumetric flow and is particularly useful when comparing filled versus unfilled
packaging grades or polymers with different filler content per ISO 1133-1 Procedure
B.

  What MFI values are typical for common packaging plastics and what do they indicate?

MFI values directly indicate the processability of packaging polymers. Low MFI values(
0.1–2 g/10 min) indicate high molecular weight, high-strength materials suited for
heavy-duty packaging films and pipes. Medium MFI values (2–10 g/10 min) suit blown
film extrusion for flexible packaging. High MFI values (above 10 g/10 min) indicate
easy-flow grades used for injection-moulded containers and caps. Per ASTM D1238 
and ISO 1133-1, consistent MFI values across batches confirm raw material uniformity
for packaging production.

  Which packaging polymers are tested using a Melt Flow Index tester?

Melt flow index testing per ASTM D1238 and ISO 1133-1 is applied to all major thermoplastics
used in packaging including HDPE (bottles, drums, rigid containers), LDPE and LLDPE(
flexible films, shrink films, pouches), polypropylene PP (woven sacks, BOPP films,
caps and closures), polystyrene PS (food trays, disposable containers), and PET (
bottles, laminates). For PVC packaging materials, ASTM D3364 specifies the applicable
melt flow rate test method.

  How does MFI testing support quality control in a packaging film manufacturing
line?

MFI testing provides a rapid, economical indication of the average molecular weight
and processing viscosity of a polymer, enabling incoming material inspection, lot-
to-lot consistency verification, and basic processability screening across the packaging
industry. When MFI values deviate from specification per ASTM D1238 or ISO 1133-
1, it signals batch-to-batch variation in raw material supply — allowing manufacturers
to reject non-conforming resin before it enters the extrusion or lamination line
and causes film defects or seal failures.

  How should a Melt Flow Index tester be calibrated and maintained for accurate 
results?

Melt flow index testers must be calibrated using certified reference materials with
known MFR values traceable to national standards, ensuring results comply with ASTM
D1238:2023 and ISO 1133-1:2022 requirements. The capillary die dimensions of 2.095
mm diameter and 8.000 mm length must be verified regularly. The barrel, piston, 
and die must be cleaned after every test to prevent polymer degradation contamination.
Calibration records must be maintained per ISO 17025 laboratory competence requirements
for traceability and regulatory submissions.

## Related Machines

[⌊Digital Torque Tester NJY-20⌉⌊Digital Torque Tester NJY-20⌉[

[Digital Torque Tester NJY-20](https://flexitest.in/packaging-testing-equipments/container-bottle-cap/)

NJY-20 precisely measures cap opening & locking torque for bottles and packages,
compliant with ASTM D2063, D3198 & D3474.

[View Details ](https://flexitest.in/packaging-testing-equipments/container-bottle-cap/)

[⌊MA 160 Moisture Analyzer⌉⌊MA 160 Moisture Analyzer⌉[

[MA 160 Moisture Analyzer](https://flexitest.in/packaging-testing-equipments/moisture-analyser/)

Fast, precise moisture analysis for solids, liquids & pastes with AURI heating and
up to 100 programmable methods.

[View Details ](https://flexitest.in/packaging-testing-equipments/moisture-analyser/)

[⌊Digital Torque Tester C612M⌉⌊Digital Torque Tester C612M⌉[

[Digital Torque Tester C612M](https://flexitest.in/packaging-testing-equipments/container-bottle-cap/)

C612M automatically measures cap application & removal torque with high precision,
compliant with ASTM D2063, D3198 & D3474.

[View Details ](https://flexitest.in/packaging-testing-equipments/container-bottle-cap/)

[⌊C406H Combo Tester⌉⌊C406H Combo Tester⌉[

[C406H Combo Tester](https://flexitest.in/packaging-testing-equipments/permeability-testing-instruments/combo-tester-6-cells-c406h/)

C406H delivers simultaneous 6-cell OTR & WVTR testing with coulometric & infrared
sensors, compliant with ASTM D3985.

[View Details ](https://flexitest.in/packaging-testing-equipments/permeability-testing-instruments/combo-tester-6-cells-c406h/)
