# Drying and Heating Chamber plastic polymer

- Link: https://flexitest.in/plastic-and-polymer/drying-and-heating-chamber-plastic-polymer/
- Published: 2025-01-06T07:59:33+05:30
- Author: chetanvarne

# Drying and  Heating chambers

 1. [Home](https://flexitest.in)
 2. [Plastic and Polymer](https://flexitest.in/plastic-and-polymer/)
 3. Drying and Heating Chamber plastic polymer

![Drying Heating Chamber Main banner FD56 VD23 FED 115 1 scaled](https://flexitest.
in/wp-content/uploads/2025/04/Drying-Heating-Chamber-Main-banner-FD56-VD23-FED-115-
1-scaled.webp "Drying and Heating Chamber plastic polymer 19")

## From Testing to Trust -BINDER Solutions  for Plastics and Polymers

Think of **Drying and Heating Chambers **as the essential climate control systems
for your plastic and polymer materials. In the plastic and polymer industry, these
chambers ensure that raw materials are perfectly dried and evenly heated before 
processing. By removing unwanted moisture, drying chambers prevent defects like 
bubbles and weak spots in your final products. Heating chambers, on the other hand,
prepare the materials to reach the ideal temperature for molding or extrusion, ensuring
smooth and consistent production. Together, these chambers optimize material performance,
enhance product quality, and boost manufacturing efficiency. With reliable Drying
and Heating Chambers, manufacturers can produce high-quality, durable plastic products
that meet industry standards every time.

##  Drying and Heating chambers  Machine Solutions

![Vacuum drying chambers Model VD23](https://flexitest.in/wp-content/uploads/2025/
04/VD-23-1.webp "Drying and Heating Chamber plastic polymer 20")

## 󠀁[Vacuum Drying Chambers Model VD23](https://flexitest.in/plastic-and-polymer/drying-and-heating-chamber-plastic-polymer/model-vd23-vacuum-drying-chambers/)󠁿

![Drying and Heating Chamber Model FED 115](https://flexitest.in/wp-content/uploads/
2025/04/FED-115.webp "Drying and Heating Chamber plastic polymer 21")

## 󠀁[Drying and Heating Chamber Model FED 115](https://flexitest.in/plastic-and-polymer/drying-and-heating-chamber-plastic-polymer/model-fed-115-drying-and-heating-chamber/)󠁿

![Drying and Heating Chamber Model FD 56](https://flexitest.in/wp-content/uploads/
2025/04/FD-56.webp "Drying and Heating Chamber plastic polymer 22")

## 󠀁[Drying and Heating Chamber Model FD 56](https://flexitest.in/plastic-and-polymer/drying-and-heating-chamber-plastic-polymer/model-fd-56-drying-and-heating-chamber/)󠁿

## Drying & Heating Chambers  Technical Specifications

Technical data – BINDER VD 23 (Vacuum) · FED 115 (Forced convection + enhanced timer)·
FD 56 (Forced convection)

← Swipe to see all models →

  |  Parameter |  Model Comparison |  
 |  Specification |  VD 23
Vacuum Drying |  FED 115Forced + Timer |  FD 56Forced Conv. |  
   | 🌡️ Temperature | 
 | Temperature range | +9°C above ambient to +220°C | +10°C above ambient to +300°C | +10°C above ambient to +300°C | 
 | Temperature uniformity | ±1.0 K at 100°C | ±1.2 K at 150°C | ±1.7 K at 150°C | 
 | Temperature fluctuation | ±0.1 K at 100°C | ±0.3 K at 150°C | ±0.3 K at 150°C | 
 | Heating-up time | 80 min to 100°C | 18 min to 150°C | 15 min to 150°C | 
 | Recovery time (door open 30s) | — | 4 min at 150°C | 4 min at 150°C | 
 | 🔄 Vacuum (VD 23 only) | 
 | Leak rate | 0.01 bar/h | N/A | N/A | 
 | Pressure fluctuation at 50 mbar | ±1 mbar | N/A | N/A | 
 | Pressure fluctuation at 400 mbar | ±70 mbar | N/A | N/A | 
 | 💨 Air & Convection | 
 | Convection type | Vacuum (no air flow) | Forced — adjustable fan | Forced — fixed fan | 
 | Air change rate at 100°C | N/A | 32 x/h | 80 x/h | 
 | 📦 Chamber | 
 | Interior volume | 23 litres | 116 litres | 60 litres | 
 | Interior W × H × D | 285 × 285 × 295 mm | 550 × 550 × 385 mm | 400 × 440 × 345 mm | 
 | Shelves / racks (std./max.) | 1 / 4 Patented | 2 / 5 | 2 / 4 | 
 | Load per rack | 20 kg | 30 kg | 30 kg | 
 | Permitted total load | 50 kg | 150 kg | 70 kg | 
 | 📐 Physical Dimensions | 
 | Housing W × H × D | 523 × 698 × 413 mm | 710 × 705 × 605 mm | 560 × 625 × 565 mm | 
 | Net weight (empty) | 64 kg | 54 kg | 41 kg | 
 | Wall clearance (back / sides) | 100 mm / 70 mm | 160 mm / 100 mm | 160 mm / 100 mm | 
 | ⚡ Electrical | 
 | Nominal power | 0.9 kW | 1.3 kW | 1.1 kW | 
 | Rated voltage | 200–230V / 100–120V | 200–230V / 100–120V | 200–230V / 100–120V | 
 | Energy consumption at 100°C | 140 Wh/h | 215 Wh/h | 180 Wh/h | 
 | Energy consumption at 150°C | — | 340 Wh/h | 290 Wh/h | 
 | Sound pressure level | 40 dB(A) | 43 dB(A) | 43 dB(A) | 
 | 🖥️ Control & Interface | 
 | Controller display | Digital — temp & pressure | LCD + enhanced timer | LCD display | 
 | Fan speed control | N/A | Adjustable | Fixed | 
 | Ethernet interface | ✓ Standard | ✓ Standard | Optional | 
 | USB data logging | ✓ Open format | ✓ | ✓ | 
 | Inert gas connection | ✓ Standard | Optional | Optional | 
 | APT.line™ technology | — | ✓ | ✓ | 
 | 🛡️ Safety | 
 | Safety standard | Shatterproof safety glass panel | Class 2 (DIN 12880) | Class 2 (DIN 12880) | 
 | Stackable | — | ✓ | ✓ | 
 | Energy saving vs. conventional | — | Up to 30% less | Up to 30% less |

VD 23

Vacuum Drying Chamber

🌡️ Temperature

Temperature range+9°C above ambient to +220°C

Temperature uniformity±1.0 K at 100°C

Temperature fluctuation±0.1 K at 100°C

Heating-up time80 min to 100°C

Recovery time—

🔄 Vacuum

Leak rate0.01 bar/h

Pressure fluctuation at 50 mbar±1 mbar

Pressure fluctuation at 400 mbar±70 mbar

💨 Air & Convection

Convection typeVacuum (no air flow)

Air change rate at 100°CN/A

📦 Chamber

Interior volume23 litres

Interior W × H × D285 × 285 × 295 mm

Shelves / racks1 / 4 Patented

Load per rack20 kg

Permitted total load50 kg

📐 Physical

Housing W × H × D523 × 698 × 413 mm

Net weight64 kg

Wall clearance100 mm / 70 mm

⚡ Electrical

Nominal power0.9 kW

Rated voltage200–230V / 100–120V

Energy at 100°C140 Wh/h

Energy at 150°C—

Sound pressure40 dB(A)

🖥️ Control & Interface

Controller displayDigital — temp & pressure

Fan speed controlN/A

Ethernet interface✓ Standard

USB data logging✓ Open format

Inert gas connection✓ Standard

APT.line™ technology—

🛡️ Safety

Safety standardShatterproof safety glass

Stackable—

Energy saving—

FED 115

Forced Convection + Enhanced Timer

🌡️ Temperature

Temperature range+10°C above ambient to +300°C

Temperature uniformity±1.2 K at 150°C

Temperature fluctuation±0.3 K at 150°C

Heating-up time18 min to 150°C

Recovery time4 min at 150°C

🔄 Vacuum

Leak rateN/A

Pressure fluctuation at 50 mbarN/A

Pressure fluctuation at 400 mbarN/A

💨 Air & Convection

Convection typeForced — adjustable fan

Air change rate at 100°C32 x/h

📦 Chamber

Interior volume116 litres

Interior W × H × D550 × 550 × 385 mm

Shelves / racks2 / 5

Load per rack30 kg

Permitted total load150 kg

📐 Physical

Housing W × H × D710 × 705 × 605 mm

Net weight54 kg

Wall clearance160 mm / 100 mm

⚡ Electrical

Nominal power1.3 kW

Rated voltage200–230V / 100–120V

Energy at 100°C215 Wh/h

Energy at 150°C340 Wh/h

Sound pressure43 dB(A)

🖥️ Control & Interface

Controller displayLCD + enhanced timer

Fan speed controlAdjustable

Ethernet interface✓ Standard

USB data logging✓

Inert gas connectionOptional

APT.line™ technology✓

🛡️ Safety

Safety standardClass 2 (DIN 12880)

Stackable✓

Energy savingUp to 30% less

FD 56

Forced Convection Standard

🌡️ Temperature

Temperature range+10°C above ambient to +300°C

Temperature uniformity±1.7 K at 150°C

Temperature fluctuation±0.3 K at 150°C

Heating-up time15 min to 150°C

Recovery time4 min at 150°C

🔄 Vacuum

Leak rateN/A

Pressure fluctuation at 50 mbarN/A

Pressure fluctuation at 400 mbarN/A

💨 Air & Convection

Convection typeForced — fixed fan

Air change rate at 100°C80 x/h

📦 Chamber

Interior volume60 litres

Interior W × H × D400 × 440 × 345 mm

Shelves / racks2 / 4

Load per rack30 kg

Permitted total load70 kg

📐 Physical

Housing W × H × D560 × 625 × 565 mm

Net weight41 kg

Wall clearance160 mm / 100 mm

⚡ Electrical

Nominal power1.1 kW

Rated voltage200–230V / 100–120V

Energy at 100°C180 Wh/h

Energy at 150°C290 Wh/h

Sound pressure43 dB(A)

🖥️ Control & Interface

Controller displayLCD display

Fan speed controlFixed

Ethernet interfaceOptional

USB data logging✓

Inert gas connectionOptional

APT.line™ technology✓

🛡️ Safety

Safety standardClass 2 (DIN 12880)

Stackable✓

Energy savingUp to 30% less

VD 23 — Vacuum Drying

FED 115 — Forced + Enhanced Timer

FD 56 — Forced Convection

Same value — all models

* Source: BINDER GmbH official product pages — binder-world.com. All specifications
verified September 2026.