## Melt Flow Testing: The Foundation of  Reliable Plastic Solutions

In the plastic and polymer industry, the **Melt Flow Indexer** is like testing a
material’s “flexibility” in molten form. It helps to understand the flow properties
of a thermo plastic elastomer. It measures how easily melted plastic flows through
a tiny orifice under specific heat and pressure. This flow rate helps manufacturers
understand the material’s viscosity, predicting how it will behave during molding
or extrusion. By knowing this, they can ensure the plastic fills molds seamlessly,
creating high-quality products without defects.
It also aids in customizing materials
for specific applications by tweaking flow properties to meet unique requirements.
Ultimately, the Melt Flow Indexer is an essential tool that saves time and resources
by preventing production hiccups, helping manufacturers deliver reliable and efficient
products to the market.

##  Melt Indexers  MP 1200

![MP1200 Packaging product banner new 1 scaled e1755692406343](https://flexitest.
in/wp-content/uploads/2025/04/MP1200-Packaging-product-banner-new-1-scaled-e1755692406343.
webp "Melt Flow Indexer- Plastic and Polymers 9")

![MP1200 Packaging inner bg compressed scaled min e1747225620706](https://flexitest.
in/wp-content/uploads/2025/04/MP1200-Packaging-inner-bg-compressed-scaled-min-e1747225620706.
webp "Melt Flow Indexer- Plastic and Polymers 10")

**MP 1200** measures the melt flow rate of thermoplastic materials under controlled
temperature and load. Use it to compare material batches and check suitability for
moulding or extrusion. Manual and motorised configurations are available; ask Flexitest
which setup and accessories suit your materials and test method.

 Get Instant Quote

####  Submit Your Details to Download Brochure!

  Name

  Email

  Phone Number

  Company Name

  Company Location

   By clicking the button, I agree and consent to the company’s [Privacy Policy](https://flexitest.in/privacy-policy)

 Traceable-Certified-weights-Auto-load-to-test

 Manual-Automatic-cutter-Quick-die-release

 Single-or-multiple-MFI-Unit-Capablity

 Piston-Displacement-Transducer-Enable-procedure-B-testing

 Peel-test-2

 Heated-barrel-with-PID-zone-control

## Features

 *     Three-zone band heater
 *     Touch-screen control
 *     Quick die release
 *     USB connectivity
 *     Tapered weight design
 *     Powerful data analysis and control software

## Customized Solutions for Melt Flow Indexer

Complete technical specifications for the MP 1200 Melt Flow Indexer — temperature
control, transducer accuracy and physical dimensions.

← Swipe to see all specifications →

     MP 1200 Melt Flow Indexer — Key Specifications  |  Specification |  Value / Range |  
   | Conformance & Standards |  | 
 | Conformance | ASTM D1238 & D3364 · ISO 1133-1 & -2 · BS2782 · DIN 53735 · JIS K7210 | 
 | Temperature |  | 
 | Operating temperature | 410°C max. | 
 | Temperature control | ±0.1°C | 
 | Spatial temperature variation | ±0.1°C | 
 | Temperature controller | Three-zone PID | 
 | Temperature sensors | Platinum RTDs (3) | 
 | Timing |  | 
 | Displayed capture time | 0.01 second | 
 | Internal timing interval | 0.001 second | 
 | Display & Data |  | 
 | Display | 7.1″ LCD touchscreen · 800 × 480 resolution | 
 | Data entry | Touchscreen display | 
 | Communications port | USB | 
 | Weights |  | 
 | Weight material & tolerance | Stainless steel or Aluminium · ±0.5% tolerance | 
 | PPDT-1200 Actuating Switch |  | 
 | Transducer accuracy | ±0.001 in (ASTM) · ±0.02 mm (ISO) | 
 | MWLD-1200 Motorised Weight Support |  | 
 | Transducer accuracy | ±0.1 mm (±0.01 in) | 
 | Physical |  | 
 | Overall dimensions — basic unit (W×D×H) | 458 mm / 18 in × 394 mm / 15.5 in × 521 mm / 20.5 in | 
 | Overall dimensions — motorised unit (H) | 762 mm / 30 in (to top of weight cage, platform lowered) | 
 | Net weight — basic unit | 21 kg / 46 lb | 
 | Net weight — motorised unit | 32 kg / 71 lb | 
 | Gross weight — basic unit | 32 kg / 70 lb | 
 | Gross weight — motorised unit | 43 kg / 95 lb |

MP 1200 Melt Flow Indexer

Key Specifications

Conformance & Standards

ConformanceASTM D1238 & D3364 · ISO 1133-1 & -2 · BS2782 · DIN 53735 · JIS K7210

Temperature

Max. temperature410°C

Temp. control±0.1°C

Spatial variation±0.1°C

ControllerThree-zone PID

SensorsPlatinum RTDs (3)

Timing

Displayed capture0.01 second

Internal interval0.001 second

Display & Data

Display7.1″ LCD touchscreen · 800×480

Data entryTouchscreen display

CommunicationsUSB

Weights

MaterialStainless steel or Aluminium

Tolerance±0.5%

PPDT-1200 Actuating Switch

Accuracy (ASTM)±0.001 in

Accuracy (ISO)±0.02 mm

MWLD-1200 Motorised Weight

Transducer accuracy±0.1 mm (±0.01 in)

Physical Dimensions

Basic unit W×D×H458×394×521 mm (18×15.5×20.5 in)

Motorised unit H762 mm / 30 in

Net wt. — basic21 kg / 46 lb

Net wt. — motorised32 kg / 71 lb

Gross wt. — basic32 kg / 70 lb

Gross wt. — motorised43 kg / 95 lb

**Weights not included in listed mass figures.** Basic and motorised unit weights
exclude test weights and optional accessories. Confirm the full configuration with
Flexitest before ordering.

We'll confirm the latest configuration, accessories and applicable test standards
with your quotation.

## FAQ's

 Frequently Asked Questions (FAQs) – Common questions from QC managers, procurement
officers, and R&D teams.

  What Melt Flow Indexer models does Flexitest supply for plastic and polymer testing?

Flexitest supplies two Tinius Olsen Melt Flow Indexer models: the **MP600 Extrusion
Plastometer** for standard MFR measurement per ASTM D1238 and ISO 1133; and the **
MP1200 / MP1200M** – available in manual (MP1200) and motorised (MP1200M) configurations,
with three-zone band heater, colour touchscreen, programmable piston displacement
transducer (PPDT) for MVR testing, optional automatic cutter, and Tinius Olsen Horizon
software for unlimited test storage and SPC reporting. Both comply with **ASTM D1238**(
Procedures A, B, C, D) and **ISO 1133-1 & 2**.

  What is a Melt Flow Index (MFI) and why is it important for plastic processing?

The Melt Flow Index (MFI) – also called Melt Flow Rate (MFR) – measures the mass
of polymer in grams flowing through a standard die (2.095 mm diameter) in 10 minutes
under a specified temperature and load, expressed as **g/10 min** per **ASTM D1238**/**
ISO 1133**. It is the primary quality control parameter for thermoplastic resins
because it indicates viscosity, molecular weight, and processability. High MFI =
lower molecular weight = easier flow (injection moulding). Low MFI = higher molecular
weight = better melt strength (extrusion, blow moulding). Every resin datasheet 
specifies an MFI value – batch-to-batch MFI consistency confirms the resin grade
has not changed or degraded.

  What plastics and resins can be tested - and to which standards?

**ASTM D1238 Procedure A** (Manual Cut Method) is the gravimetric method – the operator
manually cuts extrudate samples at timed intervals and weighs them to calculate 
the Melt Mass Flow Rate (MFR) in g/10 min. It is the standard routine QC method.**
ASTM D1238 Procedure B** (Automatically Timed Flow Rate) uses an encoder-based Programmable
Piston Displacement Transducer (PPDT) to automatically measure piston displacement
over time — calculating both MFR (Melt Mass Flow Rate) and MVR (Melt Volume Flow
Rate, cm³/10 min) without manual cutting. Procedure B is more automated, more repeatable,
and required when both MFR and MVR are needed. The Tinius Olsen MP1200 with PPDT
performs both procedures. The international equivalent procedures are defined in**
ISO 1133-1** (Procedure A) and **ISO 1133-2** (Procedure B).

  What is MVR and when should it be measured instead of MFR?

**MFR (Melt Mass Flow Rate)** is measured in **g/10 min** per **ASTM D1238 Procedure
A / ISO 1133-1** – the standard for most commodity resin QC. **MVR (Melt Volume 
Flow Rate)** is measured in **cm³/10 min** per **ASTM D1238 Procedure B / ISO 1133-
2** using the PPDT – it measures the volume of polymer extruded rather than mass.
MVR is preferred when comparing resins of different densities (e.g., filled vs unfilled
grades), characterising recycled polymers with variable density, or when the resin
supplier specifies MVR on the material datasheet. MVR is also used to calculate 
Melt Density from the ratio of MFR to MVR. The Tinius Olsen MP1200M with PPDT reports
both MFR and MVR simultaneously in a single test.

  What plastics can be tested with the Tinius Olsen MFI and at what test conditions?

The MP600 and MP1200 cover all common thermoplastic resins per **ASTM D1238** / **
ISO 1133** standard test conditions: **Polyethylene (PE)** – 190°C / 2.16 kg (ASTM
D1238 Condition 190/2.16); **Polypropylene (PP)** – 230°C / 2.16 kg; **ABS** – 220
°C / 10 kg; **Polycarbonate (PC)** – 300°C / 1.2 kg; **Nylon PA6/PA66** – 275°C /
0.325 kg; **PET** – 250°C / 2.16 kg; **PMMA** – 230°C / 3.8 kg; **POM (Acetal)**–
190°C / 2.16 kg. The MP1200’s three-zone band heater achieves precise temperature
control across the full range – essential for high-temperature engineering resins
like PC and Nylon where temperature uniformity directly affects result accuracy 
per **ISO 1133-2**.

  What is the Tinius Olsen Horizon software and what does it do for MFI testing?

**Tinius Olsen Horizon software** integrates with the MP1200M to provide: unlimited
storage of test settings and results; user-configurable test reports in PDF, Excel,
and LIMS-compatible formats; **SPC (Statistical Process Control) charts** for batch-
to-batch MFR/MVR trend monitoring; method libraries with standard-specific test 
routines for ASTM D1238 and ISO 1133; and automatic calculation of Flow Rate Ratio(
FRR) – the ratio of MFR at two different loads on one charge, which characterises
molecular weight distribution per **ASTM D1238 Procedure C/D**. Horizon software
transforms the MFI instrument from a single measurement device into a complete resin
QC documentation system. Flexitest configures Horizon with your resin-specific methods
and report formats at installation.

  How does MFI testing support incoming raw material QC and supplier qualification?

Every batch of plastic resin received from a supplier should be tested against the
MFI specification on the material datasheet per **ASTM D1238** / **ISO 1133** before
it enters the process. An MFI value outside specification indicates: a different
molecular weight grade was supplied; the resin was degraded during transport or 
storage; or contamination has occurred — any of which will cause processing problems
and defective parts. Documented MFI test records on incoming batches provide: traceable
evidence of raw material conformance for **IATF 16949** and **ISO 9001** quality
systems; supplier qualification data for OEM customer submissions; and the baseline
MFR/MVR data needed to detect long-term supplier drift before it reaches production.

## Related Machines

[⌊MA 160 Moisture Analyzer⌉⌊MA 160 Moisture Analyzer⌉[

[MA 160 Moisture Analyzer](https://flexitest.in/automotive/testing-instruments-for-auto-ancilary-products/ma-160-moisture-analyzer-2/)

Halogen Moisture Analyser MA - 160 measures moisture content in automotive plastics,
textiles and powders by loss on drying.

[View Details ](https://flexitest.in/automotive/testing-instruments-for-auto-ancilary-products/ma-160-moisture-analyzer-2/)

[⌊High Energy Impact Tester- Plastic and Polymer⌉⌊High Energy Impact Tester- Plastic
and Polymer⌉[

[High Energy Impact Tester- Plastic and Polymer](https://flexitest.in/plastic-and-polymer/high-energy-impact-tester-plastic-and-polymer/)

Compare IT503 and IT504 low-energy impact testers for Charpy and Izod testing of
plastics. Ask Flexitest for help choosing your test configuration.

[View Details ](https://flexitest.in/plastic-and-polymer/high-energy-impact-tester-plastic-and-polymer/)

[⌊HDT Vicat Tester⌉⌊HDT Vicat Tester⌉[

[HDT Vicat Tester](https://flexitest.in/plastic-and-polymer/hdt-vicat-tester/)

HDT and Vicat softening point tester determines heat deflection temperature and 
softening point of plastics to ISO 75 and ISO 306.

[View Details ](https://flexitest.in/plastic-and-polymer/hdt-vicat-tester/)

[⌊Accelerated Weathering Chamber – Plastic Polymer⌉⌊Accelerated Weathering Chamber–
Plastic Polymer⌉[

[Accelerated Weathering Chamber – Plastic Polymer](https://flexitest.in/plastic-and-polymer/accelerated-weathering-chamber-plastic-polymer/)

Accelerated weathering chambers for plastics and polymers, reproducing UV, heat 
and moisture exposure to predict colour, gloss and strength loss.

[View Details ](https://flexitest.in/plastic-and-polymer/accelerated-weathering-chamber-plastic-polymer/)