# Salt Spray Chamber for Plastic & Polymer Material Testing

- Link: https://flexitest.in/plastic-and-polymer/salt-spray-chamber-for-plastics/
- Published: 2026-10-06T16:06:04+05:30
- Author: kamal

# Salt Spray Chamber for Plastic & Polymer Material Testing

 1. [Home](https://flexitest.in)
 2. [Plastic and Polymer](https://flexitest.in/plastic-and-polymer/)
 3. Salt Spray Chamber for Plastic & Polymer Material Testing

##  programmable 880T  salt spray chamber

Flexitest manufactures and supplies programmable salt spray chambers for coated 
plastic and polymer components in India. Metallised or chrome-plated trims, painted
housings and parts with metal inserts may need corrosion or exposure testing under
a customer specification. Share the material, finish and required procedure so Flexitest
can review the 880/T, 881/T or 882/T configuration.

![Flexitest 880 t product banner](https://flexitest.in/wp-content/uploads/2026/10/
Flexitest_880_t_product_banner.webp "Salt Spray Chamber for Plastic & Polymer Material
Testing 3")

![T Product banner Paint mobile](https://flexitest.in/wp-content/uploads/2026/10/
T-Product-banner-Paint-mobile-1-1024x1024.png "Salt Spray Chamber for Plastic & 
Polymer Material Testing 4")

![Flexitest 880T salt spray chamber](https://flexitest.in/wp-content/uploads/2026/
10/Flexitest-880T-tiles-image.webp "Salt Spray Chamber for Plastic & Polymer Material
Testing 5")

For plastic and polymer components, share the required exposure procedure, whether
it references ISO 4611, ASTM D1735, ASTM B117, ASTM B368 or ISO 9227. Flexitest 
will review the specified method and chamber configuration for your coated, plated
or insert-moulded samples. A reference to a standard does not establish support 
for every exposure condition it describes.

 Get Instant Quote

####  Submit Your Details to Download Brochure!

  Name

  Email

  Phone Number

  Company Name

  Company Location

   By clicking the button, I agree and consent to the company’s [Privacy Policy](https://flexitest.in/privacy-policy)

![Salt Spray Corrosion Comparison](https://flexitest.in/wp-content/uploads/2026/
10/Salt-Spray-Corrosion-Comparison.webp "Salt Spray Chamber for Plastic & Polymer
Material Testing 6")

 Damp Heat, Water & Salt Mist Exposure

 Water Fog Coating Resistance Test

 Salt Spray Corrosion Comparison

 Flexitest 880T tiles image

## Features

 1. **Standards-based chamber selection:** Specify the required ISO 4611 exposure, 
    ASTM D1735 procedure, ASTM B117, ASTM B368, ISO 9227 method or ASTM G85 annex. 
    Ask Flexitest to confirm the configuration. DIN 50021 is a withdrawn legacy standard.
 2. **Gentle, controlled heating:** Heating wires on the outer layer of the inner plate
    warm the chamber by radiation, with PID control. Working room RT+5 °C to 55 °C 
    with ≤ ±2 °C uniformity, so temperature-sensitive polymers see a steady environment.
 3. **Salt fog and water fog requirements:** Share the required procedure with Flexitest
    to confirm the fluid supply, chamber conditions and cleaning requirements. Changing
    the tank liquid alone does not establish ASTM D1735 compliance.
 4. **Flexible sample rack for moulded parts:** Rods, V-shaped glass-fibre brackets(
    20° ± 5°) and a mesh plate hold flat plaques, housings, trims and odd-shaped mouldings.
    Rack capacity is above 200 kg.
 5. **Long-duration ageing tests:** Continuous fog up to 999.9 hours, or intervals 
    of up to 99 h 59 min spray and 99 h 59 min pause, set on the TEMI 880 7-inch touch
    screen.
 6. **Clean results, no drip marks:** The inclined lid keeps condensate off sample 
    surfaces, which matters for gloss, colour and appearance ratings on plastics.
 7. **Data you can report:** Up to 360 days of logged temperature and test data, USB
    program and data transfer, and RS232 connection for up to 16 chambers.

 *     Standards-based chamber selection: Specify the required ISO 4611 exposure,
   ASTM D1735 procedure, ASTM B117, ASTM B368, ISO 9227 method or ASTM G85 annex.
   Ask Flexitest to confirm the configuration. DIN 50021 is a withdrawn legacy standard.
 *     Gentle, controlled heating: Heating wires on the outer layer of the inner
   plate warm the chamber by radiation, with PID control. Working room RT+5 °C to
   55 °C with ≤ ±2 °C uniformity, so temperature-sensitive polymers see a steady
   environment.
 *     Salt fog and water fog requirements: Share the required procedure with Flexitest
   to confirm the fluid supply, chamber conditions and cleaning requirements. Changing
   the tank liquid alone does not establish ASTM D1735 compliance.
 *     Flexible sample rack for moulded parts: Rods, V-shaped glass-fibre brackets(
   20° ± 5°) and a mesh plate hold flat plaques, housings, trims and odd-shaped 
   mouldings. Rack capacity is above 200 kg.
 *     Long-duration ageing tests: Continuous fog up to 999.9 hours, or intervals
   of up to 99 h 59 min spray and 99 h 59 min pause, set on the TEMI 880 7-inch 
   touch screen.
 *     Clean results, no drip marks: The inclined lid keeps condensate off sample
   surfaces, which matters for gloss, colour and appearance ratings on plastics.
 *     Data you can report: Up to 360 days of logged temperature and test data, 
   USB program and data transfer, and RS232 connection for up to 16 chambers.

 Get Free Quote

## Salt Spray  Chamber

 Programmable Corrosion Test System — Automotive Grade

Technical information for the Flexitest 880/T programmable salt spray chamber. Confirm
the model and configuration against your required test method before ordering.

  |  Specification |  Model 880T Details |  
   | Sample Rack & Loading |  | 
 | Rack Layers | Three layers, corrosion-resistant rods | 
 | Rack Brackets | V-shaped glass-fibre, 20° ± 5° angle | 
 | Base | Mesh base plate for large parts | 
 | Load Capacity | > 200 kg, uniformly distributed | 
 | Temperature & Stability |  | 
 | CASS Working Room Temp | 50 °C — reached in under 45 min | 
 | CASS Saturated Air Barrel Temp | 63 °C — reached in under 45 min | 
 | Temperature Stability | ≤ ±0.5 °C | 
 | Spray & Fog Control |  | 
 | Interval Fog Cycle | Spray and pause — each up to 99 h 59 min | 
 | Continuous Fog Duration | Up to 999.9 hours | 
 | Salt Solution Feed | Peristaltic pump from external large tank | 
 | Test Method Requirements |  | 
 | Neutral Salt Spray (NSS) | ASTM B117 — Confirm the specified NSS procedure and chamber configuration with Flexitest. | 
 | CASS Test | ASTM B368 — Confirm the CASS procedure, specimen preparation and chamber configuration with Flexitest. | 
 | Modified Cyclic Salt Fog | ASTM G85 — Specify the annex and cycle; confirm the required chamber configuration with Flexitest. | 
 | Corrodkote Test | ASTM B380 — Corrodkote procedure; confirm the required apparatus and configuration with Flexitest. | 
 | DIN Standard | DIN 50021 — Withdrawn legacy standard; confirm the contractual method and edition before ordering. | 
 | Typical Automotive Applications |  | 
 | Fasteners | Zinc and zinc-nickel plated fasteners | 
 | Body Parts | E-coated and painted body panels | 
 | Trim | Decorative chrome trims | 
 | Aluminium | Anodised aluminium components | 
 | Chassis & Brakes | Brake parts, chassis components, electrical connectors |

Test Standards — Confirm Configuration

  |  Standard |  Test Type |  Application |  
   | ASTM B117 | Neutral Salt Spray (NSS) | Confirm the specified NSS procedure and chamber configuration with Flexitest. | 
 | ASTM B368 | CASS (Copper-Accelerated) | Confirm the CASS procedure, specimen preparation and chamber configuration with Flexitest. | 
 | ASTM G85 | Modified Salt Fog | Specify the annex and cycle; confirm the required chamber configuration with Flexitest. | 
 | ASTM B380 | Corrodkote | Corrodkote procedure; confirm the required apparatus and configuration with Flexitest. | 
 | ISO 9227 | NSS / AASS / CASS | Specify NSS, AASS or CASS and the required edition; confirm configuration with Flexitest. | 
 | DIN 50021 | Withdrawn legacy standard | Withdrawn legacy standard; confirm the contractual method and edition before ordering. |

Model 880T Salt Spray Chamber

Programmable Salt Spray Chamber

Sample Rack & Loading

Rack Layers3 layers, corrosion-resistant rods

Rack BracketsV-shaped glass-fibre, 20° ± 5°

Load Capacity> 200 kg

Temperature

CASS Room Temp50 °C (<45 min)

CASS Barrel Temp63 °C (<45 min)

Stability≤ ±0.5 °C

Spray & Fog

Interval Fog CycleUp to 99 h 59 min each

Continuous FogUp to 999.9 hours

Salt Solution FeedPeristaltic pump

Test Method Requirements

ASTM B117Confirm the specified NSS procedure and chamber configuration with Flexitest.

ASTM B368Confirm the CASS procedure, specimen preparation and chamber configuration
with Flexitest.

ASTM G85Specify the annex and cycle; confirm the required chamber configuration 
with Flexitest.

ASTM B380Corrodkote procedure; confirm the required apparatus and configuration 
with Flexitest.

ISO 9227Specify NSS, AASS or CASS and the required edition; confirm configuration
with Flexitest.

DIN 50021Withdrawn legacy standard; confirm the contractual method and edition before
ordering.

Automotive Applications

FastenersZinc / zinc-nickel plated

Body PartsE-coated & painted panels

TrimDecorative chrome trims

AluminiumAnodised components

Chassis & BrakesBrake parts, connectors

Test Standards — Confirm Configuration

ASTM B117NSS

Confirm the specified NSS procedure and chamber configuration with Flexitest.

ASTM B368CASS

Confirm the CASS procedure, specimen preparation and chamber configuration with 
Flexitest.

ASTM G85Annex-specific

Specify the annex and cycle; confirm the required chamber configuration with Flexitest.

ASTM B380Corrodkote

Corrodkote procedure; confirm the required apparatus and configuration with Flexitest.

ISO 9227Method-specific

Specify NSS, AASS or CASS and the required edition; confirm configuration with Flexitest.

DIN 50021Withdrawn

Withdrawn legacy standard; confirm the contractual method and edition before ordering.

Need help selecting the right Salt Spray Chamber?

Share your test standard, sample size and cycle requirement — we'll recommend the
right model for your corrosion testing lab.

## FAQs

  Frequently Asked Questions (FAQs) – Salt Spray Chamber

  Why do plastic parts need salt spray testing?

Most plastic products contain or carry something that can corrode or degrade: plated
or painted surfaces, metal inserts, or additives sensitive to moisture. Salt spray
testing reveals blistering, adhesion loss, discolouration and insert corrosion before
parts are released.

  What is ISO 4611?

ISO 4611 describes how to expose plastics to damp heat, water spray and salt mist,
and how to assess changes afterwards in properties such as appearance, mass, dimensions
and mechanical strength.

  Can I test chrome-plated plastic parts?

Share the plating system and the method required by your customer, such as ASTM 
B368 CASS, ASTM B117 or the specified ISO 9227 method. Flexitest can review the 
chamber configuration and specimen arrangement before you order.

  Can the chamber run a water fog test instead of salt spray?

Ask Flexitest to confirm the chamber configuration against the required ASTM D1735
procedure before running a water fog test. Changing the tank liquid alone does not
establish compliance with that method.

  How do I choose the right chamber size for polymer samples?

 Match the working-room volume to your largest part and the number of samples per
test, leaving space for fog to circulate. Share your sample sizes with our team 
at sales@flexitest.in or +91 93263 25135, and we will recommend the 880/T, 881/T
or 882/T.

## Related Machines

[⌊Accelerated Weathering Chamber – Plastic Polymer⌉⌊Accelerated Weathering Chamber–
Plastic Polymer⌉[

[Accelerated Weathering Chamber – Plastic Polymer](https://flexitest.in/plastic-and-polymer/accelerated-weathering-chamber-plastic-polymer/)

Accelerated weathering chambers for plastics and polymers, reproducing UV, heat 
and moisture exposure to predict colour, gloss and strength loss.

[View Details ](https://flexitest.in/plastic-and-polymer/accelerated-weathering-chamber-plastic-polymer/)

[⌊Colour Measurement Instruments for Plastics and Polymers⌉⌊Colour Measurement Instruments
for Plastics and Polymers⌉[

[Colour Measurement Instruments for Plastics and Polymers](https://flexitest.in/plastic-and-polymer/flexitest-colour-measurement-solutions/)

Compare TS7700, YH1000 and YS6060 for reflected colour, transmitted colour, haze
and luminous transmittance testing in plastic and polymer QC.

[View Details ](https://flexitest.in/plastic-and-polymer/flexitest-colour-measurement-solutions/)

[⌊Drying and Heating Chamber plastic polymer⌉⌊Drying and Heating Chamber plastic
polymer⌉[

[Drying and Heating Chamber plastic polymer](https://flexitest.in/plastic-and-polymer/drying-and-heating-chamber-plastic-polymer/)

BINDER drying and heating chambers for plastics and polymers, removing moisture 
before processing to prevent bubbles, cracks and weak spots.

[View Details ](https://flexitest.in/plastic-and-polymer/drying-and-heating-chamber-plastic-polymer/)

[⌊HDT Vicat Tester⌉⌊HDT Vicat Tester⌉[

[HDT Vicat Tester](https://flexitest.in/plastic-and-polymer/hdt-vicat-tester/)

HDT and Vicat softening point tester determines heat deflection temperature and 
softening point of plastics to ISO 75 and ISO 306.

[View Details ](https://flexitest.in/plastic-and-polymer/hdt-vicat-tester/)