Salt Spray Chamber for Plastic & Polymer Material Testing
- Home
- Plastic and Polymer
- Salt Spray Chamber for Plastic & Polymer Material Testing
programmable 880T salt spray chamber
Flexitest manufactures and supplies programmable salt spray chambers for coated plastic and polymer components in India. Metallised or chrome-plated trims, painted housings and parts with metal inserts may need corrosion or exposure testing under a customer specification. Share the material, finish and required procedure so Flexitest can review the 880/T, 881/T or 882/T configuration.
For plastic and polymer components, share the required exposure procedure, whether it references ISO 4611, ASTM D1735, ASTM B117, ASTM B368 or ISO 9227. Flexitest will review the specified method and chamber configuration for your coated, plated or insert-moulded samples. A reference to a standard does not establish support for every exposure condition it describes.
Submit Your Details to Download Brochure!
Features
- Standards-based chamber selection: Specify the required ISO 4611 exposure, ASTM D1735 procedure, ASTM B117, ASTM B368, ISO 9227 method or ASTM G85 annex. Ask Flexitest to confirm the configuration. DIN 50021 is a withdrawn legacy standard.
- Gentle, controlled heating: Heating wires on the outer layer of the inner plate warm the chamber by radiation, with PID control. Working room RT+5 °C to 55 °C with ≤ ±2 °C uniformity, so temperature-sensitive polymers see a steady environment.
- Salt fog and water fog requirements: Share the required procedure with Flexitest to confirm the fluid supply, chamber conditions and cleaning requirements. Changing the tank liquid alone does not establish ASTM D1735 compliance.
- Flexible sample rack for moulded parts: Rods, V-shaped glass-fibre brackets (20° ± 5°) and a mesh plate hold flat plaques, housings, trims and odd-shaped mouldings. Rack capacity is above 200 kg.
- Long-duration ageing tests: Continuous fog up to 999.9 hours, or intervals of up to 99 h 59 min spray and 99 h 59 min pause, set on the TEMI 880 7-inch touch screen.
- Clean results, no drip marks: The inclined lid keeps condensate off sample surfaces, which matters for gloss, colour and appearance ratings on plastics.
- Data you can report: Up to 360 days of logged temperature and test data, USB program and data transfer, and RS232 connection for up to 16 chambers.
- Standards-based chamber selection: Specify the required ISO 4611 exposure, ASTM D1735 procedure, ASTM B117, ASTM B368, ISO 9227 method or ASTM G85 annex. Ask Flexitest to confirm the configuration. DIN 50021 is a withdrawn legacy standard.
- Gentle, controlled heating: Heating wires on the outer layer of the inner plate warm the chamber by radiation, with PID control. Working room RT+5 °C to 55 °C with ≤ ±2 °C uniformity, so temperature-sensitive polymers see a steady environment.
- Salt fog and water fog requirements: Share the required procedure with Flexitest to confirm the fluid supply, chamber conditions and cleaning requirements. Changing the tank liquid alone does not establish ASTM D1735 compliance.
- Flexible sample rack for moulded parts: Rods, V-shaped glass-fibre brackets (20° ± 5°) and a mesh plate hold flat plaques, housings, trims and odd-shaped mouldings. Rack capacity is above 200 kg.
- Long-duration ageing tests: Continuous fog up to 999.9 hours, or intervals of up to 99 h 59 min spray and 99 h 59 min pause, set on the TEMI 880 7-inch touch screen.
- Clean results, no drip marks: The inclined lid keeps condensate off sample surfaces, which matters for gloss, colour and appearance ratings on plastics.
- Data you can report: Up to 360 days of logged temperature and test data, USB program and data transfer, and RS232 connection for up to 16 chambers.
Salt Spray Chamber
Technical information for the Flexitest 880/T programmable salt spray chamber. Confirm the model and configuration against your required test method before ordering.
| Specification | Model 880T Details |
|---|---|
| Sample Rack & Loading | |
| Rack Layers | Three layers, corrosion-resistant rods |
| Rack Brackets | V-shaped glass-fibre, 20° ± 5° angle |
| Base | Mesh base plate for large parts |
| Load Capacity | > 200 kg, uniformly distributed |
| Temperature & Stability | |
| CASS Working Room Temp | 50 °C — reached in under 45 min |
| CASS Saturated Air Barrel Temp | 63 °C — reached in under 45 min |
| Temperature Stability | ≤ ±0.5 °C |
| Spray & Fog Control | |
| Interval Fog Cycle | Spray and pause — each up to 99 h 59 min |
| Continuous Fog Duration | Up to 999.9 hours |
| Salt Solution Feed | Peristaltic pump from external large tank |
| Test Method Requirements | |
| Neutral Salt Spray (NSS) | ASTM B117 — Confirm the specified NSS procedure and chamber configuration with Flexitest. |
| CASS Test | ASTM B368 — Confirm the CASS procedure, specimen preparation and chamber configuration with Flexitest. |
| Modified Cyclic Salt Fog | ASTM G85 — Specify the annex and cycle; confirm the required chamber configuration with Flexitest. |
| Corrodkote Test | ASTM B380 — Corrodkote procedure; confirm the required apparatus and configuration with Flexitest. |
| DIN Standard | DIN 50021 — Withdrawn legacy standard; confirm the contractual method and edition before ordering. |
| Typical Automotive Applications | |
| Fasteners | Zinc and zinc-nickel plated fasteners |
| Body Parts | E-coated and painted body panels |
| Trim | Decorative chrome trims |
| Aluminium | Anodised aluminium components |
| Chassis & Brakes | Brake parts, chassis components, electrical connectors |
| Standard | Test Type | Application |
|---|---|---|
| ASTM B117 | Neutral Salt Spray (NSS) | Confirm the specified NSS procedure and chamber configuration with Flexitest. |
| ASTM B368 | CASS (Copper-Accelerated) | Confirm the CASS procedure, specimen preparation and chamber configuration with Flexitest. |
| ASTM G85 | Modified Salt Fog | Specify the annex and cycle; confirm the required chamber configuration with Flexitest. |
| ASTM B380 | Corrodkote | Corrodkote procedure; confirm the required apparatus and configuration with Flexitest. |
| ISO 9227 | NSS / AASS / CASS | Specify NSS, AASS or CASS and the required edition; confirm configuration with Flexitest. |
| DIN 50021 | Withdrawn legacy standard | Withdrawn legacy standard; confirm the contractual method and edition before ordering. |
Need help selecting the right Salt Spray Chamber?
Share your test standard, sample size and cycle requirement — we'll recommend the right model for your corrosion testing lab.
FAQs
Why do plastic parts need salt spray testing?
Most plastic products contain or carry something that can corrode or degrade: plated or painted surfaces, metal inserts, or additives sensitive to moisture. Salt spray testing reveals blistering, adhesion loss, discolouration and insert corrosion before parts are released.
What is ISO 4611?
ISO 4611 describes how to expose plastics to damp heat, water spray and salt mist, and how to assess changes afterwards in properties such as appearance, mass, dimensions and mechanical strength.
Can I test chrome-plated plastic parts?
Share the plating system and the method required by your customer, such as ASTM B368 CASS, ASTM B117 or the specified ISO 9227 method. Flexitest can review the chamber configuration and specimen arrangement before you order.
Can the chamber run a water fog test instead of salt spray?
Ask Flexitest to confirm the chamber configuration against the required ASTM D1735 procedure before running a water fog test. Changing the tank liquid alone does not establish compliance with that method.
How do I choose the right chamber size for polymer samples?
Related Machines

Accelerated weathering chambers for plastics and polymers, reproducing UV, heat and moisture exposure to predict colour, gloss and strength loss.
View Details →
Compare TS7700, YH1000 and YS6060 for reflected colour, transmitted colour, haze and luminous transmittance testing in plastic and polymer QC.
View Details →
BINDER drying and heating chambers for plastics and polymers, removing moisture before processing to prevent bubbles, cracks and weak spots.
View Details →
HDT and Vicat softening point tester determines heat deflection temperature and softening point of plastics to ISO 75 and ISO 306.
View Details →