Salt Spray Chamber for Automotive Parts & Component Testing
- Home
- Automotive
- Salt Spray Chamber for Automotive Parts & Component Testing
programmable 880T salt spray chamber
Flexitest manufactures and supplies programmable salt spray chambers for automotive component testing in India. The 880/T, 881/T and 882/T models provide controlled salt-fog exposure for evaluating fasteners, plated and painted parts, chassis components, trims and electrical connectors. Share your required test method, sample dimensions and acceptance criteria so we can confirm the appropriate chamber configuration.
For an overview of test methods and chamber selection, read our salt spray chamber guide.
Automotive corrosion requirements may specify ASTM B117, ASTM B368 (CASS), ISO 9227 or a particular ASTM G85 annex. Share the test method and edition, required cycle, sample dimensions and acceptance criteria so Flexitest can confirm the appropriate chamber configuration for your components.
Submit Your Details to Download Brochure!
Features
- Standards-based chamber selection: Specify ASTM B117, ASTM B368 (CASS), the required ISO 9227 method or ASTM G85 annex. Ask Flexitest to confirm the configuration for your procedure. ASTM B380 uses the Corrodkote procedure; DIN 50021 is a withdrawn legacy standard.
- Heavy-duty sample rack: Three layers with corrosion-resistant rods, V-shaped glass-fibre brackets (20° ± 5°) and a mesh base plate for large parts. Uniform load capacity of more than 200 kg.
- Programmable spray/pause operation: Program spray and pause periods of up to 99 h 59 min each, or run continuous fog up to 999.9 hours for specified exposure periods.
- Accurate CASS temperatures: Working room reaches 50 °C and the saturated air barrel reaches 63 °C in under 45 minutes each, with temperature stability of ≤ ±0.5 °C.
- No nozzle clogging on long runs: A peristaltic pump feeds salt solution from an external large tank, avoiding siphon-nozzle crystallisation and keeping fog fall-out steady for 1,000-hour tests.
- Programmable TEMI 880 touch screen: 7-inch 800 × 480 colour display with program, fixed-value and timed start/stop modes, so tests start and stop without an operator present.
- Traceable test records: Logs set values, measured values and time for up to 360 days at a 2-minute interval. Transfer programs and data by USB, or network up to 16 chambers over RS232 for central monitoring.
Salt Spray Chamber
Technical information for the Flexitest 880/T programmable salt spray chamber. Confirm the model and configuration against your required test method before ordering.
| Specification | Model 880T Details |
|---|---|
| Sample Rack & Loading | |
| Rack Layers | Three layers, corrosion-resistant rods |
| Rack Brackets | V-shaped glass-fibre, 20° ± 5° angle |
| Base | Mesh base plate for large parts |
| Load Capacity | > 200 kg, uniformly distributed |
| Temperature & Stability | |
| CASS Working Room Temp | 50 °C — reached in under 45 min |
| CASS Saturated Air Barrel Temp | 63 °C — reached in under 45 min |
| Temperature Stability | ≤ ±0.5 °C |
| Spray & Fog Control | |
| Interval Fog Cycle | Spray and pause — each up to 99 h 59 min |
| Continuous Fog Duration | Up to 999.9 hours |
| Salt Solution Feed | Peristaltic pump from external large tank |
| Test Method Requirements | |
| Neutral Salt Spray (NSS) | ASTM B117 / ISO 9227 NSS — confirm the specified configuration with Flexitest. |
| CASS Test | ASTM B368 / ISO 9227 CASS — confirm the required method and configuration. |
| Modified Cyclic Salt Fog | ASTM G85 — specify the annex and cycle; configuration review required. |
| Corrodkote Test | ASTM B380 — Corrodkote procedure; confirm the required configuration. |
| DIN Standard | DIN 50021 — withdrawn legacy standard; confirm the contractual edition and procedure. |
| Typical Automotive Applications | |
| Fasteners | Zinc and zinc-nickel plated fasteners |
| Body Parts | E-coated and painted body panels |
| Trim | Decorative chrome trims |
| Aluminium | Anodised aluminium components |
| Chassis & Brakes | Brake parts, chassis components, electrical connectors |
| Standard | Test Type | Selection Requirement |
|---|---|---|
| ASTM B117 | Neutral salt spray / salt-fog apparatus | Specify exposure and acceptance criteria in the product or customer specification. |
| ASTM B368 | Copper-accelerated acetic acid-salt spray (CASS) | Confirm the required CASS procedure and chamber configuration. |
| ASTM G85 | Modified salt spray methods | Five distinct annexes; specify the required annex and cycle. |
| ASTM B380 | Corrodkote procedure | Confirm the procedure and chamber configuration; not a blanket salt-fog capability claim. |
| ISO 9227 | NSS / AASS / CASS | Specify the method and applicable product or customer requirements. |
| DIN 50021 | Withdrawn legacy standard | If contractually specified, confirm the required edition and procedure. |
Need help selecting the right Salt Spray Chamber?
Share your test standard, sample size and cycle requirement — we'll recommend the right model for your corrosion testing lab.
FAQs
Which salt spray standards do automotive OEMs usually specify?
ASTM B117 covers salt-fog apparatus and operation. ISO 9227 includes NSS, AASS and CASS methods, and ASTM B368 covers CASS testing. For ASTM G85, specify the required annex and cycle. Follow the applicable product or customer specification, and ask Flexitest to confirm the required chamber configuration.
How long are salt spray tests for automotive fasteners?
Test duration and acceptance criteria come from the applicable product or customer specification, including the coating and the corrosion endpoint being assessed. ASTM B117 does not prescribe a universal exposure period. Salt-spray hours should not be converted directly into years of service.
Can the chamber hold heavy components like brackets and castings?
Yes. The mesh plate on the lower rack layer takes large parts, and the rack is rated for more than 200 kg of uniformly distributed load.
Does the chamber support cyclic corrosion testing?
The Flexitest brochure specifies programmable spray and pause periods of up to 99 h 59 min each. Spray/pause programming alone does not establish support for every cyclic corrosion method. For ASTM G85, provide the required annex and cycle so Flexitest can confirm the appropriate chamber configuration, including any required humidity, drying or gas-exposure steps.
Can I get test data for PPAP and audit files?
Yes. The controller stores up to 360 days of temperature and test data, which you can export by USB or view on a PC through the RS232 link.
Related Machines

Compare xenon and UV accelerated weathering chambers for automotive materials in India. Explore benchtop and larger models, sample capacity and configuration.
View Details →
BINDER drying and heating chambers with natural or forced convection, built for drying, ageing and heat treatment of automotive samples.
View Details →
Tinius Olsen universal testing machines for automotive materials: tensile, compression and elongation testing for quality control and R&D.
View Details →
BINDER dynamic climate chambers simulate temperature and humidity extremes so automotive components are validated before they reach the road.
View Details →