Dynamic Climate Chamber

  1. Home
  2. Automotive
  3. Dynamic climate chambers
dynamic climate chamber main banner 1
dynamic climate chamber main banner mobile 1x

Fortify Your Brand with Binder’s State-of-the-Art Climate Chambers for Automotive Quality Assurance

Dynamic climate chambers play a pivotal role in the automotive industry by providing controlled environments to test and validate vehicle performance under various climatic conditions. These chambers are essential for ensuring that automotive components and systems can withstand extreme temperatures, humidity, and other environmental factors.An environmental simulation chamber is suitable for complex temperature profiles in the range of -40 °C or -70 °C to 180 °C.

Key Considerations

Key Consideration when buying your Dynamic Climate Chamber

Dynamic Climate Chamber Point 1

Temperature Range

Dynamic Climate Chamber Point 2

Humidity Regulation

Dynamic Climate Chamber Point 3

Homogeneous Temperature Distribution

Dynamic Climate Chamber Point 4

Measurement Precision

Dynamic Climate Chamber Point 5

Operation And Safety

Key Considerations

Key Consideration when buying your Dynamic Climate Chamber

binder guide temperature range
binder guide humidity regulation
binder guide homogeneous temperature distribution
binder guide measurement precision
binder guide operation safety

Binder MKF series

Technical Specification

Binder Dynamic Climate Chambers
Series MK · MKF · MKT · MKFT - Model & Feature Comparison
← Scroll to see all series →
Features Series MK Series MKF Series MKT Series MKFT
Model
Model 56L✓✓--
Model 115L✓✓✓✓
Model 240L✓✓✓✓
Model 400L✓✓--
Model 720L✓✓✓✓
Model 1020L✓✓--
General Data
Temperature range [°C]-40…180-40…180-70…180-70…180
Humidity range [%rh]-10…98-10…98
Ethernet interface✓✓✓✓
USB interface✓✓✓✓
Forced convection✓✓✓✓
Controller and Timer Functions
Controller displayTFT Touch
Ramp function✓✓✓✓
Time delayed ON✓✓✓✓
Programming option✓✓✓✓
Class 1 temperature safety device✓✓✓✓
Class 2 independent adjustable temperature safety device✓✓✓✓
Temperature alarm, acoustic✓✓✓✓
Temperature alarm, visual✓✓✓✓
Series MK
Temperature only · -40 to 180°C
Available Models
56L 115L 240L 400L 720L 1020L
General Data
Temperature range-40…180°C
Humidity range-
Ethernet interface✓
USB interface✓
Forced convection✓
Controller Functions
Controller displayTFT Touch
Ramp function✓
Time delayed ON✓
Programming option✓
Class 1 temp. safety device✓
Class 2 adjustable safety device✓
Temperature alarm, acoustic✓
Temperature alarm, visual✓
Series MKF
Temperature + Humidity · -40 to 180°C · 10-98% rh
Available Models
56L 115L 240L 400L 720L 1020L
General Data
Temperature range-40…180°C
Humidity range10…98% rh
Ethernet interface✓
USB interface✓
Forced convection✓
Controller Functions
Controller displayTFT Touch
Ramp function✓
Time delayed ON✓
Programming option✓
Class 1 temp. safety device✓
Class 2 adjustable safety device✓
Temperature alarm, acoustic✓
Temperature alarm, visual✓
Series MKT
Low Temperature · -70 to 180°C
Available Models
56L 115L 240L 400L 720L 1020L
General Data
Temperature range-70…180°C
Humidity range-
Ethernet interface✓
USB interface✓
Forced convection✓
Controller Functions
Controller displayTFT Touch
Ramp function✓
Time delayed ON✓
Programming option✓
Class 1 temp. safety device✓
Class 2 adjustable safety device✓
Temperature alarm, acoustic✓
Temperature alarm, visual✓
Series MKFT
Low Temp + Humidity · -70 to 180°C · 10-98% rh
Available Models
56L 115L 240L 400L 720L 1020L
General Data
Temperature range-70…180°C
Humidity range10…98% rh
Ethernet interface✓
USB interface✓
Forced convection✓
Controller Functions
Controller displayTFT Touch
Ramp function✓
Time delayed ON✓
Programming option✓
Class 1 temp. safety device✓
Class 2 adjustable safety device✓
Temperature alarm, acoustic✓
Temperature alarm, visual✓
✓ Standard equipment  |  - Not available in this series

Need help selecting the right Dynamic Climate Chamber?

Share your temperature range, humidity requirements and test standards — we'll recommend the right BINDER series and model for your application.

dynamic climate chamber specification

FAQ's

 Frequently Asked Questions (FAQs) –Dynamic Climate Chamber r
A dynamic climate chamber changes temperature (and humidity in MKF/MKFT models) rapidly in a controlled way. Automotive manufacturers use it to test components, electronics, plastics, seals and materials under heat, cold and humidity cycles before they go into a vehicle – so failures are found in the lab, not on the road.
Both control temperature and humidity (10-98% RH). MKF covers -40°C to +180°C. MKFT extends the low end to -70°C using cascade compressor cooling. Choose MKF for standard cold-and-heat tests; choose MKFT when your test standard needs temperatures below -40°C.
MKF: -40°C to +180°C. MKFT: -70°C to +180°C. Humidity: 10-98% RH (within 10°C to 95°C climate range). Humidity fluctuation: ±2.5% RH. Temperature fluctuation: ±0.1 to ±0.5 K depending on setpoint.
Average rates (IEC 60068-3-5, unloaded): MKF 56 – 5 K/min heating, 5 K/min cooling. MKF 400 – 5 K/min / 5 K/min. MKF 1020 – 5.5 K/min / 5 K/min. MKFT 240 – 5 K/min / 4.2 K/min. MKFT 720 – 4.8 K/min / 4 K/min.
Match interior volume to your sample size and leave space for airflow: 60L (MKF 56), 228L (MKFT 240), 417L (MKF 400), 734L (MKFT 720), 991L (MKF 1020). Max loads: 60-200 kg. If samples generate heat, share details with Flexitest to check heat compensation data.
DIN and IEC cold, heat and climate tests; ramp rates per IEC 60068-3-5. Widely used for automotive and electronics temperature/humidity cycling tests. Share your specific test standard with Flexitest to confirm the right model.
Visual and audible alarms, programmable condensation protection, heated viewing window and door heating, water tank low-level alarm (MKFT). Class 2 independent adjustable temperature safety device (DIN 12880) built into MKFT; optional on MKF – switches off heating if main controller fails.
Touchscreen controller with time-segment and real-time programming, ramp function, Ethernet interface. MKF 56 and MKFT have internal data logger with USB read-out. BINDER APT-COM software for recording and documentation; GLP edition for FDA 21 CFR Part 11 compliance. 4 zero-voltage relay contacts.
MKF 56: single-phase 200-230V / 50Hz / 2.8 kW. Others: 400V 3-phase / 50Hz / 6-12.5 kW. Wall clearance: 300mm back, 200mm sides (MKF 400: 500mm / 300mm). Integrated 20L water tank on MKF 400, MKF 1020 and MKFT models.
Yes – installation, operator training, maintenance contracts, 24/7 service support. Calibration up to 27 temperature points (DIN 12880) and humidity. IQ/OQ and IQ/OQ/PQ qualification documents available for audited environments.
×

Highlights

Scroll to Top