HDT Vicat Tester

  1. Home
  2. Plastic and Polymer
  3. HDT Vicat Tester
HDT Vicat Tester product banner scaled e1750663715410
hdt vicat tester product banner mobile

Measure Thermal Resistance of Plastics Accurately

The Flexitest HDT & Vicat Softening Temperature Tester is designed to accurately evaluate the thermal performance and heat resistance of plastic and polymer materials. The HDT (Heat Deflection Temperature), also known as DTUL (Deflection Temperature Under Load), measures the temperature at which a test specimen deforms under a specified bending load.

During testing, the specimen is immersed in a temperature-controlled heating medium, with the temperature increased at a specified rate until the required deflection occurs. Vicat testing determines the softening temperature of materials under a specified load using a standard needle.

HDT Vicat Tester inner banner min scaled e1747299234654

In the plastic and polymer industry, this machine is used to determine the exact temperatures at which materials begin to soften or deform under load ! The Heat Deflection Temperature (HDT) and the Vicat Softening Point. By revealing these critical thermal thresholds, it helps manufacturers select the right plastics that can withstand specific temperature conditions. This ensures products like car interiors, electrical housings, and outdoor equipment remain reliable and safe even when temperatures rise. Essentially, the HDT/Vicat Tester is vital for designing heat-resistant plastic products that perform flawlessly in real-world conditions.

Pendulum impact testers are versatile and reliable machines designed to fully comply with the specifications outlined in ASTM E23, EN10045-2 and ISO 148. Today, the Model IT406 and the Model IT542 are widely recognized as the standards of the industry for impact testing.

Features

Technical Specifications

Select a model to view detailed specifications. Both models perform HDT and Vicat Softening Point tests as per ISO 75, ISO 306 and ASTM D648.

Model Comparison — VT3 vs VT6

Both models perform HDT and Vicat Softening Point tests as per ISO 75, ISO 306 and ASTM D648.

Feature HDVT3 3-Station HDVT6 6-Station
Test stations36
Test methodsHDT + VicatHDT + Vicat
Temperature range23 – 300 °C23 – 300 °C
Heating rate50 or 120 °C/hr (2°C/min)50 or 120 °C/hr (2°C/min)
Temperature resolution0.1 °C0.1 °C
Temperature sensorPlatinum RTD (per station)Platinum RTD (per station)
Deflection / penetrationLVDT — 0.001 mm resolutionLVDT — 0.001 mm resolution
Bath capacity11 litres (stainless steel)Larger bath (stainless steel)
Cooldown time~20 minutesRapid — built-in heat exchanger
Heat exchangerMulti-wrap cooling coilBuilt-in heat exchanger (faster)
Pneumatic station lift✓ Yes✓ Yes
Exhaust fan (oil fumes)✓ Yes✓ Yes
Specimen basket✓ Yes✓ Yes
Fully automatic cycle✓ Yes✓ Yes
SoftwareHorizon (standalone or PC)Horizon (standalone or PC)
Power supply220/240 V, 50/60 Hz, 4.5 kW220/240 V, 50/60 Hz
Best suited forSmaller labs, R&D, low throughputProduction labs, high throughput

Technical Specifications

Parameter Value / Detail
StandardsISO 75 · ISO 306 · ASTM D648 · ASTM D1525
Temperature range23 °C to 300 °C
Heating rate50 °C/hr or 120 °C/hr (2 °C/min)
Temperature resolution0.1 °C
Temp. sensor (per station)Platinum RTD + safety overtemp switch
Deflection measurementLVDT — 0.001 mm resolution
HDT load (ISO 75 flatwise)0.45 MPa (76 g nominal on 4 × 10 mm specimen)
Vicat needle area1 mm² flat-ended; penetration depth 1.0 mm
Edgewise anvil span100 mm (standard)
Flatwise anvil span64 mm (optional, pre-drilled)
Bath mediumHeat transfer fluid (silicone oil)
Bath capacity (VT3)11 litres (stainless steel)
Cooldown time~20 min (VT3) · Rapid with heat exchanger (VT6)
Data acquisition1000 Hz via RJ-45 PC connection
Control / displayColour touchscreen LCD; stored protocols; SI / metric / English units
ResultsAverage + standard deviation; auto-zeroing; real-time display
Air supply (pneumatics)Clean dry air, 50 µm filter, 40 psi (2.7 bar); supply 65 psi
Power supply220/240 V · 50/60 Hz · 4.5 kW ±10%
Dimensions (VT3)585 mm (H) × 813 mm (W) × 635 mm (D)
Weight (VT3)87 kg

* VT6 dimensions and weight may differ. Contact Flexitest for model-specific datasheet.

Technical Specifications

Select a model to view detailed specifications. Both models perform HDT and Vicat Softening Point tests as per ISO 75, ISO 306 and ASTM D648.

🌡️
HDVT3
HDT & Vicat — 3-Station
Test methodsHDT + Vicat Softening Point
StandardsISO 75 · ISO 306 · ASTM D648 · ASTM D1525
Test stations3
Temperature range23 °C to 300 °C
Heating rate50 °C/hr or 120 °C/hr (2 °C/min)
Temp resolution0.1 °C
Temperature sensorPlatinum RTD (per station) + overtemp switch
Deflection / penetrationLVDT — 0.001 mm resolution
HDT load (ISO 75)0.45 MPa (76 g on 4 × 10 mm specimen)
Vicat needle1 mm² flat-ended; penetration depth 1.0 mm
Bath capacity11 litres (stainless steel)
Bath mediumSilicone oil (heat transfer fluid)
Cooldown time~20 minutes
Heat exchangerMulti-wrap cooling coil
Pneumatic lift✓ Yes
Automatic cycle✓ Fully automatic
Data acquisition1000 Hz via RJ-45 PC connection
Display / softwareColour touchscreen LCD · Horizon software
Power supply220/240 V · 50/60 Hz · 4.5 kW
Dimensions585 (H) × 813 (W) × 635 (D) mm
Weight87 kg
🌡️
HDVT6
HDT & Vicat — 6-Station
Test methodsHDT + Vicat Softening Point
StandardsISO 75 · ISO 306 · ASTM D648 · ASTM D1525
Test stations6
Temperature range23 °C to 300 °C
Heating rate50 °C/hr or 120 °C/hr (2 °C/min)
Temp resolution0.1 °C
Temperature sensorPlatinum RTD (per station) + overtemp switch
Deflection / penetrationLVDT — 0.001 mm resolution
HDT load (ISO 75)0.45 MPa (76 g on 4 × 10 mm specimen)
Vicat needle1 mm² flat-ended; penetration depth 1.0 mm
Bath capacityLarger bath (stainless steel)
Bath mediumSilicone oil (heat transfer fluid)
Cooldown timeRapid — built-in heat exchanger
Heat exchanger✓ Built-in (faster cooldown)
Pneumatic lift✓ Yes
Automatic cycle✓ Fully automatic
Data acquisition1000 Hz via RJ-45 PC connection
Display / softwareColour touchscreen LCD · Horizon software
Power supply220/240 V · 50/60 Hz
DimensionsContact Flexitest for datasheet
Best suited forProduction labs · High throughput
* Confirm heating rate, test method (HDT / Vicat), and load configuration for your specific standard before ordering. Bath capacity and cooldown time are based on the HDVT3 model; confirm HDVT6 dimensions with Flexitest.

FAQ's

 Frequently Asked Questions (FAQs) – HDT Vicat Tester

 The Heat Deflection Temperature (HDT) test measures the temperature at which a plastic specimen deflects by a fixed amount under a constant load. It tells you how well the material maintains its shape and structural rigidity when exposed to elevated temperatures -critical for applications like car interiors, electrical housings, and outdoor equipment.

The Vicat Softening Point test measures the temperature at which a plastic specimen is penetrated to a depth of 1 mm by a flat-ended needle under a defined load. It indicates the temperature at which the plastic begins to soften significantly -an important parameter for moulding, forming, and application design.

HDT measures the temperature at which a bar specimen deflects under a bending load -it evaluates structural stiffness under heat. Vicat measures penetration of a needle into the surface -it evaluates the onset of softening. Both tests are used to determine the upper service temperature of plastics, and many labs run both on the same machine.

The HDT / Vicat tester is designed to comply with: ISO 75 -Heat deflection temperature of plastics ISO 306 -Vicat softening temperature of plastics ASTM D648 -Deflection temperature of plastics under flexural load Confirm the exact standards required for your application with our technical team before ordering.

Yes, the tester is available in two configurations:

  • VT3 (3-station) -tests 3 specimens simultaneously; suited for smaller labs or lower throughput
  • VT6 (6-station) -tests 6 specimens simultaneously; suited for production labs and higher throughput

The 6-station (603) model also includes a built-in heat exchanger for rapid cooldown between test runs.

The machine controls the entire test cycle automatically -heating rate, load application, deflection or penetration detection, and result recording. This removes operator error and ensures repeatable, standard-compliant results without manual intervention.
The pneumatic station lift raises and lowers the specimen holder automatically for easy loading and unloading. This allows operators to insert and remove specimens without touching the hot oil bath directly, improving safety and reducing the risk of burns.

The HDT / Vicat tester is designed for plastics and polymers, including thermoplastics (PP, PE, ABS, PVC, Nylon, Polycarbonate, PET, PBT), thermosets, composites, and polymer blends. It is used across automotive, electrical, packaging, and consumer goods industries to verify thermal performance.

Yes. Flexitest provides free installation & commissioning at your facility, operator training & demonstration, calibration services, Annual Maintenance Contracts (AMC), maintenance & repair, and online training. With over 600 active customers across India, our team supports labs in Mumbai, Delhi, Ahmedabad, Vadodara, Pune, Hyderabad, and Chennai.
Download the brochure directly from this page (3-Station Units, Common Station Parts, Horizon Software). To get a quote or speak to our technical team: Email: sales@flexitest.in | Phone: +91 22-4970 6073 | Mobile: +91 93263 25135. We will recommend the right model (VT3 or VT6) and configuration for your lab.

Related Machines

TS7700 Portable Spectrophotometer for Plastic Colour QC

Spectrophotometer Measure reflected colour and batch variation on moulded plastic parts, plaques and polymer surfaces with the portable TS7700.

View Details
YH1000 Haze Meter

Haze Meter measures haze and light transmittance of transparent automotive plastics, glazing and lamp covers YH1000 | Flexitest

View Details
YS6060 Benchtop Spectrophotometer for Plastics

Spectrophotometer measure reflected and transmitted colour in opaque, translucent and transparent polymer samples with YS6060.

View Details
Accelerated Weathering Chamber – Plastic Polymer

Accelerated weathering chambers for plastics and polymers, reproducing UV, heat and moisture exposure to predict colour, gloss and strength loss.

View Details
×

Highlights

Scroll to Top
Flexitest logo