Leave a plastic bottle in a parked car on a May afternoon and it may come back bent out of shape. An HDT Vicat tester finds the exact temperature at which a plastic starts to bend or soften, so manufacturers know the limit before the product ever reaches you.
Why heat is a big deal for plastic
Plastic is light, affordable, and easy to shape, which is why it is in almost everything we use. Its weak point is heat. Every plastic has a temperature at which it stops acting like a firm, solid part and starts to sag, bend or go soft.
That limit matters more than most people realise:
- A car dashboard sits under the windscreen in direct summer sun.
- A switchboard or charger housing warms up every time current flows through it.
- A water tank, pipe or garden chair spends years outdoors.
If the plastic softens too early, the part warps, comes loose or fails. So before a material is chosen for a product, someone has to measure how much heat it can take. That is the one job of an HDT Vicat tester.
Two tests in one machine
The machine runs two different tests. Both warm a small plastic sample slowly and catch the moment it gives way.
HDT (Heat Deflection Temperature) answers the question: at what temperature does this plastic start to bend under a load? A bar of plastic rests on two supports, like a small bridge. A weighted rod presses down on the middle. The temperature at which the bar bends by a set amount is its HDT. You will also see it called DTUL, Deflection Temperature Under Load. It is the same test.
Vicat softening temperature answers a slightly different question: at what temperature does the material itself turn soft? Here a flat-tipped needle with a tip area of 1 mm² presses on the sample. The temperature at which the needle sinks 1 mm into the plastic is the Vicat softening point.
| HDT / DTUL | Vicat softening point | |
|---|---|---|
| What presses on the sample | A rod on the middle of a supported bar | A needle with a 1 mm² tip |
| What the machine watches for | The bar bending by a set amount | The needle sinking 1 mm into the surface |
| What the result tells you | When a part will lose its shape under load | When the material turns soft |
| Test standards | ASTM D648, ISO 75 | ASTM D1525, ISO 306 |
Both tests follow international standards. That means your result can be compared fairly with a result from any other lab that follows the same standard.
How the machine runs a test
Once the operator loads the samples and presses start, the machine controls the whole test cycle on its own.
- Load the sample. The test stations rise out of the bath on air pressure. The operator places a sample at each station.
- Apply the load. A weight sits on each loading rod. The rods glide on air bearings, so almost no friction disturbs the reading.
- Lower into the bath. The stations go down into a stainless steel bath of heat-transfer oil. A stirrer keeps the oil at an even temperature throughout.
- Heat slowly and steadily. The oil warms at a fixed rate, either 120°C per hour (2°C per minute) or 50°C per hour. The bath works from 23°C up to 300°C.
- Measure every tiny movement. A sensor on each rod tracks movement in steps of 0.001 mm. A separate temperature sensor sits at each station.
- Record the result. The moment a sample bends or the needle sinks by the set amount, the machine notes the temperature. It also reports the average and standard deviation across samples.
- Cool down. A built-in cooling coil brings the oil back down automatically, ready for the next batch.
The touchscreen shows temperature and movement for every station in real time. Test settings can be saved and recalled, so the same test is run the same way every time.
HDVT3 or HDVT6: which one fits your lab?
The main difference is how many samples you can test at once: up to 3 on the HDVT3 and up to 6 on the HDVT6. Both are Tinius Olsen bench-top machines, supplied and supported in India by Flexitest.
| HDVT3 | HDVT6 | |
|---|---|---|
| Test stations | 2 to 3 | 2 to 6 |
| Good fit for | Smaller labs and lower daily test volumes | Busy quality-control labs testing many samples a day |
| Size, width × depth × height (mm) | 813 × 635 × 585 | 1096 × 762 × 562 |
| Weight (kg) | 87 | 181 |
| Heat-transfer oil needed (litres) | 11 | 18 |
| Cooldown time (minutes) | 20 | 30 |
Cooldown time is the time taken to bring the oil down to within 20°C of the cooling-water temperature.
Everything else is the same on both models: the 23°C to 300°C range, 0.001 mm measurement steps, the touchscreen, the safety systems, and compliance with ASTM D648, ASTM D1525, ISO 75 and ISO 306.
What the features mean in daily use
Every feature on this machine exists to make results more trustworthy or the operator's day easier.
| Feature | What it means for you |
|---|---|
| Fully automatic test cycle | Load the samples, press start, and get on with other work. |
| Air-bearing loading rods | The rod glides almost friction-free, so the load on the sample is the true load. |
| Pneumatic station lift | The stations rise on air pressure, so samples go in and come out quickly. |
| Automatic thermal expansion correction | The metal frame also grows as it heats. The machine subtracts that, so only the plastic's movement is counted. |
| Built-in specimen basket | A sample that slips or breaks is caught instead of sinking to the bottom of the bath. |
| Exhaust fan on the bath | Oil fumes are drawn away from inside the bath. |
| Two independent over-temperature protections | A thermostat switch in the bath and a software limit both guard against overheating. There is an emergency stop button as well. |
| Built-in cooling coil | The oil cools quickly after a test, so the next batch starts sooner. |
| Colour touchscreen and Horizon software | Run the machine on its own, or connect a PC and use Tinius Olsen's Horizon software. |
| Factory calibration to NIST | The machine arrives calibrated against a recognised reference. |
Optional accessories include extra test stations, loading noses, Vicat needles, weights, and 64 mm span supports for flatwise HDT testing.
Who needs this machine?
Anyone who makes, buys or approves plastic that will face heat needs these two numbers.
- Plastic raw material and compound makers test each grade so customers know its heat limit before they buy.
- Moulders and product manufacturers check that a new batch of material behaves like the last one.
- Automotive suppliers confirm that interior parts will hold their shape in a hot cabin.
- Electrical and appliance makers make sure housings stay firm when the product warms up in use.
- Makers of outdoor products check that parts will cope with years in the sun.
- Test labs, research teams and institutes compare materials and develop new ones.
In short, the test helps you pick the right plastic for the temperature it will face, instead of finding out the hard way.
What your lab needs before installation
The machine sits on a sturdy table and needs power, air, water and a vent. Here is the checklist.
| You will need | Details |
|---|---|
| Electric power | 220/240 V, 50/60 Hz, 4.5 kW |
| Compressed air | Clean, dry air filtered to 50 microns |
| Water and a drain | A water supply to cool the bath after each test |
| Exhaust vent | An outlet for the bath's exhaust fan |
| Heat-transfer oil | 11 litres for the HDVT3, 18 litres for the HDVT6 |
| Table space | 813 × 635 mm for the HDVT3 (87 kg), 1096 × 762 mm for the HDVT6 (181 kg) |
| Room conditions | 15°C to 38°C, humidity 10% to 90% without condensation |
Common questions
Is HDT the same as the melting point?
No. HDT is the temperature at which a part starts to bend under load. That happens well before the plastic melts.
Are HDT and DTUL different tests?
No. They are two names for the same test.
Do I need both HDT and Vicat?
They answer different questions. HDT tells you when a loaded part loses its shape. Vicat tells you when the material turns soft. One machine does both. You only change the tip on the loading rod.
How many samples can I test at a time?
Up to 3 on the HDVT3 and up to 6 on the HDVT6.
How hot does the bath go?
Up to 300°C.
Can it connect to a computer?
Yes. It has a network port and works with Tinius Olsen's Horizon software. It also runs on its own from the touchscreen.
Which standards does it follow?
ASTM D648 and ISO 75 for HDT. ASTM D1525 and ISO 306 for Vicat.
Thinking about an HDT Vicat tester for your lab?
Flexitest supplies the HDVT3 and HDVT6 across India, with free installation and training from our own service engineers. After that, we stay with you through calibration, annual maintenance contracts, repairs, and live online troubleshooting. Our teams work from Mumbai, Delhi, Ahmedabad, Vadodara, Pune, Hyderabad, and Chennai, and more than 600 active customers rely on us.
See the full details and download the brochure: HDT Vicat Tester
Tell us what plastics you test and how many samples you run in a day. We will help you choose between the 3-station and 6-station model.