Integrated Air Permeability Tester

  1. Home
  2. EV Industry
  3. Integrated Air Permeability Tester
c910h c190h main banner
c910h c190h main banner mobile

Protect Product Integrity with Accurate Air Permeability, Puncture and Thickness Testing

Accurate measurement of air permeability, puncture strength, and material thickness is essential across industries – from battery separator films and packaging to filtration and paper.

Labthink’s C190H and C910H are engineered to deliver precise, repeatable results on a wide range of porous and flexible materials, including battery separator films, breathable membranes, and polymer products – helping manufacturers maintain quality and meet international test standards.

C910H Integrated air permeability tester

Advanced All-In-One Solution for Accurate Integrated Air permeability Tester for Battery Separator films

c910h product banner
c910h product banner mobile

As EV manufacturers push for higher energy density and safer lithium-ion cells, battery separator film performance has become a critical checkpoint. The C910H delivers simultaneous measurement of air permeability (Gurley), puncture strength, and thickness of battery separator films in a single automated pass – giving manufacturers and QC labs a complete picture of separator quality without the complexity of multiple instruments

image 535
Integrated Air Permeability Tester

Features

Measures air permeability, puncture strength, and thickness simultaneously
Built for manufacturers who need fast, accurate, and repeatable separator testing without multiple instruments.

Contact-Type Thickness Measurement Method:
Cemented carbide spherical head with 0.1 µm resolution for long-term accuracy in high-throughput QC lines

Mechanical-Type Puncture Strength Measurement Method
Grade 0.5 force accuracy with servo-driven control and pneumatic clamping for consistent, reliable results

Integrated Measurement with Automatic Sample Feeding
Runs all three tests on a single strip with auto scanning and dual positioning for accurate, traceable high-volume QC

Intelligent Control & Reliable Performance
12.1″ Windows touchscreen with multi-level permissions, real-time ambient monitoring, and optional CFR 21 Part 11 and DataShield™ for regulated environments 

C190H air permeability tester

c190h product banner
c190h product banner mobile

In the electric vehicle EV industry, safeguarding battery performance and longevity requires precise control over airflow through critical components. That’s exactly where the C190H Air Permeability Tester steps in. It helps engineers detect potential vulnerabilities in Battery Separator Films. A critical component in a Li-on Cell. A sub optimal Ionic Flow can be the cause of thermal Runway or short circuits in a Battery Pack.

Armed with accurate data on air permeability, manufacturers can fine-tune their material choices and designs to ensure an optimal balance between breathability and protection. The outcome is a safer, more durable EV battery system that delivers reliable performance on every road.

c190h
Integrated Air Permeability Tester

Features

C910H & C190H Technical Specifications

Advanced Air Permeability & Material Testing Systems
← Swipe to see full table →
Parameter Unit C910H C190H
🌬️Air Permeability
Measuring Range / Test Scopes/100 mL30 ~ 150030 ~ 1500
Measuring Range / Test Scopeµm/(Pa·s)0.1 ~ 40.1 ~ 4
Volume ResolutionmL0.0010.001
Volume Precision / Accuracy-1%1%
Pressure RangekPa0 ~ 20 ~ 2
Pressure AccuracykPa0.010.01
📏Thickness Measurement
Thickness Measuring Rangemm0 ~ 2N/A
Resolutionµm0.1N/A
Repeatabilityµm0.5N/A
💪Puncture Strength
Measuring RangeN0.1 ~ 50N/A
ResolutionN0.001N/A
Strength Value Precision%±0.5 (Reading)N/A
Test Speedmm/min0–500 (Any integer)N/A
Speed Accuracy%±0.5 (Reading)N/A
Measuring Intervalmm0 ~ 600N/A
Sample Feeding Speedmm/s0 ~ 50N/A
🔬Test Setup
No. of Test Cells-1 set3 sets
Specimen / Sample Size-Strip format (auto feed)≥2" × 2" (6 × 6 cm)
Specimen Thickness-≤80 mil (2 mm)≤120 mil (3 mm)
Test Area-1 in² (6.4 cm²)1 in² (6.4 cm²)
💨Air Supply
Gas Specifications-Dry air (user-supplied)Dry air (user-supplied)
Air Source Pressure-72.5–101.5 PSI / 0.5–0.7 MPa87 PSI / 600 kPa
Port / Interface Size-Φ6 mm Polyurethane PipeΦ6 mm Polyurethane Pipe
📦Physical
Dimensions (H × W × D)-29.9" × 17.7" × 21.7" (76×45×55 cm)23.6" × 19.6" × 27.5" (25×44×35 cm)
Power Supply-120 VAC ±10% 60Hz / 220 VAC ±10% 50Hz120 VAC ±10% 60Hz / 220 VAC ±10% 50Hz
Net Weight-187 lbs (85 kg)40 lbs (18 kg)
⚙️Extended Functions
GMP Computer System Requirements-OptionalN/A
DataShield™ Data Shield-OptionalN/A
CFR 21 Part 11-OptionalN/A
📋Standard Configuration
C910H Includes-Mainframe, 12.1" Windows tablet, professional software, Φ6 mm polyurethane pipe
C190H Includes-Mainframe, tablet, professional software, Φ6 mm polyurethane pipe
C910H Specification
C190H Specification
Same Specification
Not Applicable

FAQ's

 Frequently Asked Questions (FAQs) – Integrated Air Permeability Tester
What is air permeability (Gurley) testing of battery separators and why does it matter?

Air permeability testing measures how easily air passes through a porous separator film. The Labthink C190H records the time for 100 mL of air to pass through a 6.45 cm² area at 1.21 kPa. Permeability influences ion flow, so controlling it helps maintain lithium-ion cell performance and safety.

Which standards does the Labthink C190H air permeability tester reference?

The C190H references ISO 5636 (air permeance of paper and board) and TAPPI T460 (Gurley air resistance), meaning its test method is basically consistent with the methods in those standards. Results are reported in seconds per 100 mL, with an equivalent permeability value in µm/(Pa·s), which suits separator QC and supplier qualification.

How does the C190H measure air permeability?

The C190H uses a volume method in which the gas volume passing through the specimen is determined fully automatically, replacing the manual sliding cylinder method. Three independent test cells allow three specimens per run, and pressure is controlled to better than 0.01 kPa. Its test range is 30–1500 s/100 mL and 0.1–4 µm/(Pa·s).

How should a Gurley air permeability value be interpreted?

A Gurley value is the time in seconds for 100 mL of air to pass through the specimen. A longer time means lower permeability and a denser structure, while a shorter time means higher permeability. Comparing each batch against the separator specification helps detect porosity variation before cells are assembled.

What does the C910H measure in a single test?

The C910H measures air permeability, puncture strength and thickness on one separator strip in a single automated pass. Thickness covers 0–2 mm with 0.1 µm resolution, and puncture strength covers 0.1–50 N with ±0.5% accuracy. Automatic sample feeding and a strip format suit roll-to-roll separator quality control.

Which standards apply to separator tensile and puncture testing alongside air permeability?

Tensile properties of thin separator film are tested per ASTM D882 or ISO 527-3. Puncture resistance is commonly characterised using probe-based methods such as ASTM F1306. Combined with Gurley air permeability, these tests give a complete picture of separator quality. Confirm the required puncture method and probe with Flexitest before ordering.

Can the C190H test materials other than battery separators?

Yes. The C190H suits breathable membranes and related polymer products as well as battery separators. With customisation it can also test the air permeability of cigarette paper and other papers, in line with the paper-based ISO 5636 and TAPPI T460 methods. Flexitest can advise on configuration for your material.

What specimen size and thickness can the C190H and C910H test?

The C190H needs specimens of at least 6 × 6 cm and up to 3 mm thick, with a 6.4 cm² test area. Its three cells can run independently for individual results or jointly for an average. The C910H tests strip specimens up to 2 mm thick with automatic feeding, which suits continuous separator rolls.

What air supply and environmental conditions do these testers need?

Both testers need a user-supplied dry air source through a Φ6 mm polyurethane pipe: 600 kPa (87 PSI) for the C190H and 0.5–0.7 MPa for the C910H. The C190H automatically detects and records the temperature and humidity of the test environment, because ambient conditions affect results. An optional air compressor is available.

How are data integrity and calibration handled on these testers?

The C910H offers optional CFR 21 Part 11, DataShield™ and GMP computer system support for regulated environments, with multi-level user permissions. Calibration should be performed regularly, with records meeting ISO 17025 traceability requirements. Flexitest provides free installation and training, calibration, AMC and live online troubleshooting across India.

Related Machines

VAC-V2 Gas Permeability Tester

VAC-V2 Gas Permeability Tester - Accurately measures gas transmission and barrier properties of films, foils & high-barrier materials. Complies with ISO 15105-1, ISO 2556, ASTM D1434, GB/T 1038-2000, JIS K7126-1 & YBB 00082003.

View Details
Battery Cycler NEWARE

High-Precision Battery Testing Solutions - Multi-channel battery testing with SMBus communication, ultra-fast response, DCIR, pulse, cycle life & charge/discharge rate testing. Ideal for laboratory and industrial battery testing. 

View Details
Fogging Tester

FT-F1 Fogging Tester - Evaluate fogging characteristics of automotive & aircraft materials with reliable high-temperature testing. Complies with ISO 6452, DIN 75201, SAE J1756, QB/T 2728 & BS EN 14288. 

View Details
Battery Test Performance Climate Solutions

Climate and temperature test chambers for EV batteries, proving cell and module safety under extreme heat, cold and rapid climate changes.

View Details
×
Highlights
Scroll to Top
Flexitest logo