Paint / Coating / Metals Accelerated Weathering Chamber

  1. Home
  2. Paint /Coating/ Metals
  3. Accelerated Weathering Solutions- Paint / Coating
accelerated weathering chamber main banner paint
Accelerated Weathering Chamber main banner (Paint) mobile

Advanced Environmental Simulation for Material Performance

Accelerated weathering solutions are essential for the paint, coating, and metal industries, simulating years of environmental exposure in a short time. These systems replicate the effects of sunlight, moisture, temperature changes, and humidity to test how materials withstand real-world conditions. For paints and coatings, they help ensure long-lasting color, gloss, and durability. In the metal industry, they evaluate corrosion resistance and the strength of protective layers. By providing clear insights into material performance, these solutions help manufacturers create products that are durable, reliable, and built to withstand the elements.

Accelerated Weathering Chamber Solutions

Customized Solutions for Accelerated Weathering Chamber Solutions

Compare all three accelerated weathering solutions for paint, coating and metal testing - salt spray corrosion, fluorescent UV and xenon arc exposure at a glance.

← Swipe to compare all 3 chambers →

Paint & Coating Accelerated Weathering Chambers — Comparison
Specification Salt Spray Chamber
880/T · 881/T · 882/T
UV Chamber Benchtop
SB/UV/A
Xenon Test Chamber
SX/6500/H
Test Type
Exposure method Salt fog / CASS / cyclic salt spray Fluorescent UV + condensation Xenon arc + moisture / rain
Primary test for Corrosion resistance - plating, e-coat, zinc, chrome UV degradation - gloss loss, chalking, colour change Full-spectrum weathering — colour, gloss, cracking
Standards ASTM B117 ASTM B368 ASTM G85 ISO 9227 DIN 50021 ASTM G154 ISO 4892-3 ASTM D4587 ISO 16474-3 ASTM G155 ISO 4892-2 ISO 16474-2 SAE J2527
Light Source & Exposure
Light / exposure source No light — salt fog only 3 × 20 W fluorescent UV lamps (UVA 340 nm or UVB 313 nm) 1 × 6.5 kW water-cooled xenon arc lamp
Lamp / filter options — UVA 340 nm or UVB 313 nm Daylight, window-glass or UV extension filter
Moisture / rain simulation Salt fog, CASS, cyclic spray + pause Condensation cycle (programmable) Water spray / rain simulation
Temperature
Working temperature 35°C (NSS) · 50°C (CASS) · programmable RT to 70°C (programmable) Confirm with Flexitest
Temperature stability ±0.5°C Confirm with Flexitest Confirm with Flexitest
Saturated air barrel temp. 63°C (CASS) · heat-up <45 min — —
Capacity & Dimensions
Sample capacity 3-layer rack · >200 kg load · large brackets & castings 18 samples (150 × 70 mm) 63–65 samples (150 × 70 mm)
Sample arrangement V-shaped glass-fibre brackets 20° ±5° · mesh base plate Flat sample racks Rotating three-layer sample rack
Dimensions (ext.) Confirm with Flexitest (3 models available) 940 × 490 × 630 mm Confirm with Flexitest
Rated power Confirm with Flexitest 1.2 kW 6.5 kW
Power supply Confirm with Flexitest 220 V, 50 Hz, 6 A Confirm with Flexitest
Controls & Data
Controller / display TEMI 880 · 7″ 800×480 colour touchscreen Digital controller Programmable controller
Test modes Continuous fog · interval fog · CASS · timed start/stop UV + condensation cycle programmable Irradiance control · moisture cycle · programmable
Max. continuous test Fog: up to 999.9 h · Interval: up to 99 h 59 min per phase Confirm with Flexitest Confirm with Flexitest
Data logging / export 360 days · 2-min interval · USB export · RS232 (up to 16 chambers) Confirm with Flexitest Confirm with Flexitest
Typical Applications
Paint & coating use E-coat, zinc/zinc-nickel plating, chrome trim, anodised Al corrosion testing Exterior paint UV resistance, gloss retention, chalking, colour change Full-spectrum outdoor durability, fade, cracking, blistering of paints
Model details View Salt Spray Chamber → View SB/UV/A → View SX/6500/H →
Salt Spray Chamber
Models 880/T · 881/T · 882/T — Corrosion Testing
Test Type
Exposure methodSalt fog / CASS / cyclic salt spray
StandardsASTM B117, B368, G85 · ISO 9227 · DIN 50021
Temperature
Working temp.35°C (NSS) · 50°C (CASS)
Stability±0.5°C
Sat. air barrel63°C (CASS) · <45 min heat-up
Capacity
Sample load>200 kg · 3-layer rack
ArrangementV-brackets 20°±5° · mesh base plate
Controls & Data
ControllerTEMI 880 · 7″ touchscreen
Max. test timeFog: 999.9 h · Interval: 99 h 59 min/phase
Data logging360 days · USB · RS232 (16 chambers)
Application
Primary useE-coat, zinc plating, chrome trim, anodised Al
View detailsView →
SB/UV/A
UV Chamber Benchtop — Fluorescent UV
Test Type
Exposure methodFluorescent UV + condensation
StandardsASTM G154, ISO 4892-3, ASTM D4587, ISO 16474-3
Light Source
Lamps3 × 20 W fluorescent UV
Lamp optionsUVA 340 nm or UVB 313 nm
Capacity
Sample capacity18 samples (150 × 70 mm)
ArrangementFlat sample racks
Electrical
Rated power1.2 kW
Power supply220 V, 50 Hz, 6 A
Dimensions940 × 490 × 630 mm
Application
Primary useUV resistance, gloss loss, chalking, colour change
View detailsView →
SX/6500/H
Xenon Test Chamber — Full-size Xenon Arc
Test Type
Exposure methodXenon arc + moisture / rain
StandardsASTM G155, ISO 4892-2, ISO 16474-2, SAE J2527
Light Source
Lamp1 × 6.5 kW water-cooled xenon arc
Filter optionsDaylight, window-glass or UV extension
Capacity
Sample capacity63–65 samples (150 × 70 mm)
ArrangementRotating three-layer sample rack
Electrical
Rated power6.5 kW
Application
Primary useFull-spectrum durability, fade, cracking, blistering
View detailsView →

Not sure which chamber to choose? Salt spray for corrosion resistance of coatings and plating · UV chamber for UV degradation screening · Xenon arc for full-spectrum outdoor durability simulation. Contact Flexitest to match the right chamber to your test standard and sample type.

Specifications confirmed from live Flexitest pages. Dimensions and power supply for SX/6500/H and 880/T series — confirm with Flexitest before ordering.

×