Accelerated Weathering Chamber

  1. Home
  2. Plastic and Polymer
  3. Accelerated Weathering Chamber – Plastic Polymer

Advanced Environmental Simulation for Material Performance

An Accelerated Weathering Chamber is key in the plastic and polymer industry for testing how materials hold up against tough conditions like UV light, rain, and temperature changes. It helps check the durability of products, making sure they can last a long time and stay strong even when exposed to the elements. This chamber speeds up the aging process, allowing manufacturers to quickly find out if their products can withstand outdoor use. It’s an essential tool for ensuring that everything from car parts to outdoor furniture is reliable and tough.

Testing Standards

Which Standard Might Your Customer Specify?

Standards give the laboratory a common way to run and report a test. The right one depends on the material, where it is used in the vehicle and the customer’s requirement. Here are the main references you may come across.

☀️
SX/6500/H — Xenon Arc Chamber Uses a 6.5 kW water-cooled xenon arc lamp with daylight, window-glass or UV extension filters. Simulates full-spectrum sunlight including UV, visible and infrared. Suitable for exterior and interior plastic and polymer weathering tests requiring precise irradiance and moisture cycle control.
☀️ Xenon Arc
ISO 4892-2
Plastics — Xenon Arc Exposure

Methods of exposure to laboratory light sources for plastics. Covers xenon arc lamps with daylight and window-glass filter conditions for interior and exterior plastic applications. Primary reference for the SX/6500/H.

☀️ Xenon Arc
ASTM G155
Xenon Arc Equipment Operation

Standard practice for operating xenon arc light apparatus for exposure of materials. Covers equipment setup, irradiance control, filter selection and cycle operation — foundational method for xenon weathering tests.

☀️ Xenon Arc
ISO 4892-1
General Guidance — Plastic Exposure

General principles for exposure and test methods for plastics to laboratory light sources. Covers specimen preparation, mounting, exposure conditions and evaluation of colour change, gloss and mechanical properties.

🔆
ST/UV/A — Fluorescent UV Full-size Chamber Uses 8 × 40 W fluorescent UV lamps (UVA 340 nm or UVB 313 nm). Simulates UV radiation, temperature variation and condensation. Designed for outdoor furniture, automotive components, packaging and plastic and polymer products requiring high-throughput UV weathering.
🔆 Fluorescent UV
ISO 4892-3
Plastics — Fluorescent UV Exposure

Methods of exposure to laboratory light sources. Part 3 covers fluorescent UV lamps for plastics — specifies UVA 340 nm or UVB 313 nm lamp type, irradiance setting, moisture condensation cycle and specimen evaluation criteria.

🔆 Fluorescent UV
ASTM G154
Fluorescent UV Equipment Operation

Standard practice for operating fluorescent UV lamp apparatus for exposure of nonmetallic materials. Covers cycle design, irradiance control and specimen mounting — primary equipment standard for UV weathering of plastics.

🔆 Fluorescent UV
ASTM D4329
Fluorescent UV Exposure of Plastics

Standard practice for fluorescent UV exposure of plastics. Specifies lamp type, irradiance, condensation cycle and exposure duration for evaluating colour change, gloss retention and mechanical property degradation.

☀️ General
ISO 4892-1
General Guidance — Plastic Exposure

General principles for exposure and test methods for plastics to laboratory light sources. Provides guidance on specimen preparation, mounting, exposure conditions and evaluation of results applicable to all UV-exposed plastic materials.

🔆
SB/UV/A — Fluorescent UV Benchtop Chamber Compact benchtop unit with 3 × 20 W fluorescent UV lamps (UVA 340 nm or UVB 313 nm). Holds 18 samples (150 × 70 mm). Ideal for smaller labs or early-stage material screening with the same UV, condensation and temperature cycles as the full-size ST/UV/A.
🔆 Fluorescent UV
ISO 4892-3
Plastics — Fluorescent UV Exposure

Methods of exposure to laboratory light sources. Part 3 covers fluorescent UV lamps for plastics — specifies UVA 340 nm or UVB 313 nm lamp type, irradiance, moisture condensation cycle and specimen evaluation applicable to benchtop UV chambers.

🔆 Fluorescent UV
ASTM G154
Fluorescent UV Equipment Operation

Standard practice for operating fluorescent UV lamp apparatus for exposure of nonmetallic materials. Applicable to both full-size and benchtop UV chambers — covers irradiance control, cycle design and specimen mounting.

🔆 Fluorescent UV
ASTM D4329
Fluorescent UV Exposure of Plastics

Standard practice for fluorescent UV exposure of plastics. Specifies lamp type, irradiance, condensation cycle and exposure duration for evaluating colour change, gloss retention and mechanical property degradation in compact benchtop setups.

💡
Have a customer standard to meet? Share the standard code, edition and required test cycle with Flexitest. We'll check the proposed chamber's lamp type, filter, irradiance controls and sample setup against that requirement before finalising the configuration.

Compare Xenon Weathering Chambers Specification

UV chambers · ST full-size UVA / UVB · SB benchtop UVA / UVB

← Swipe to compare all chambers →

Compare Xenon & UV Weathering Chambers
☀️ Xenon Arc Chambers
🔆 Fluorescent UV Chambers
Feature SX/6500/HFull-size ST/UV/AFull-size · UVA / UVB SB/UV/ABenchtop
Light source 1 × 6.5 kW water-cooled xenon lamp 8 × 40 W fluorescent UV lamps 3 × 20 W fluorescent UV lamps
Lamp options Filter-based — daylight, window-glass or other UVA 340 nm or UVB 313 nm UVA 340 nm or UVB 313 nm
Exposure area 6,500 cm² — —
Sample capacity 63–65 samples (150 × 70 mm) 24 racks; 48 samples (150 × 70 mm) 18 samples (150 × 70 mm)
Sample arrangement Rotating three-layer sample rack Flat sample racks Flat sample racks
Rated power 6.5 kW 2 kW (max.) 1.2 kW
Power supply Confirm with Flexitest 220 V, 50 Hz; 60 Hz optional; max. 10 A 220 V, 50 Hz, 6 A
Dimensions (L × W × H) Confirm with Flexitest 1,360 × 560 × 1,290 mm 940 × 490 × 630 mm
Model details View SX/6500/H → View ST UVA / UVB → View SB/UV/A →

☀️ Xenon Arc

☀️
SX/6500/H
Xenon Arc — Full-size Chamber
Light source1 × 6.5 kW water-cooled xenon lamp
Lamp optionsFilter-based — daylight or window-glass
Exposure area6,500 cm²
Sample capacity63–65 samples (150 × 70 mm)
Sample arrangementRotating three-layer sample rack
Rated power6.5 kW
Power supplyConfirm with Flexitest
DimensionsConfirm with Flexitest
Model detailsView SX/6500/H →
🔆
ST/UV/A
Fluorescent UV — Full-size · UVA / UVB
Light source8 × 40 W fluorescent UV lamps
Lamp optionsUVA 340 nm or UVB 313 nm
Exposure area—
Sample capacity24 racks; 48 samples (150 × 70 mm)
Sample arrangementFlat sample racks
Rated power2 kW (max.)
Power supply220 V, 50 Hz; 60 Hz optional; max. 10 A
Dimensions1,360 × 560 × 1,290 mm
🔆
SB/UV/A
Fluorescent UV — Benchtop Chamber
Light source3 × 20 W fluorescent UV lamps
Lamp optionsUVA 340 nm or UVB 313 nm
Exposure area—
Sample capacity18 samples (150 × 70 mm)
Sample arrangementFlat sample racks
Rated power1.2 kW
Power supply220 V, 50 Hz, 6 A
Dimensions940 × 490 × 630 mm
Model detailsView SB/UV/A →

* Confirm the filter, irradiance measurement band, moisture cycle and utilities for your test method before ordering. Capacity is based on flat sample size; confirm holders for shaped components.

×

Highlights

Scroll to Top